We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
GE0200B - 3P SWITCH DISCONNECTOR W/BS FUSE HOLDER
MPN: GE0200B
Why Choose the GE0200B?
The Lovato GE0200B is a three-pole switch disconnector with BS fuse holder designed for dependable isolation and load switching. Rated at 200 A for AC operation, it offers Ui 800 V and Uimp 8 kV performance with IP20 frontal protection. AC21A/AC22A currents are 200 A up to 690 V, with AC23A up to 200 A at 500 V and 160 A at 690 V.
Engineered for reliability, the GE-series device delivers a 100 kA conditional short-circuit rating, 13 W max power dissipation per pole, and a mechanical life of 10,000 cycles. Screw-on plate installation simplifies panel assembly, with 13 Nm max terminal tightening torque. Suitable for -25 to 55 °C operation, up to 3000 m altitude, Pollution Degree 3, and compliant with IEC/EN 60947-1 and 60947-3.
Key Benefits
- Three-pole 200 A switching for dependable isolation across AC applications.
- BS fuse holder integration supports standardised protection and easy maintenance.
- AC21/AC22 rated 200 A up to 690 V for versatile loads.
- AC23A performance to 200 A at 500 V, 160 A at 690 V.
- Robust insulation: Ui 800 V and 8 kV impulse withstand.
- High fault tolerance with 100 kA conditional short-circuit current.
- IP20 frontal protection for safer operation during panel access.
- Designed for reliability: 10,000 mechanical cycles under demanding conditions.
Technical Specification
- Product type designation: GE
- Number of poles: 3
- Operating voltage type: AC
- Ith (IEC): 200 A
- Rated insulation voltage Ui (IEC/EN): 800 V
- Rated impulse withstand voltage Uimp: 8 kV
- Operating current Ie AC21A 400 V: 200 A
- Operating current Ie AC21A 500 V: 200 A
- Operating current Ie AC21A 690 V: 200 A
- Operating current Ie AC22A 400 V: 200 A
- Operating current Ie AC22A 500 V: 200 A
- Operating current Ie AC22A 690 V: 200 A
- Operating current Ie AC23A 400 V: 200 A
- Operating current Ie AC23A 500 V: 200 A
- Operating current Ie AC23A 690 V: 160 A
- Power dissipation per pole (max): 13 W
- Rated operational power AC23A 400 V: 110 kW
- Rated operational power AC23A 690 V: 132 kW
- Conditional short-circuit current (rms): 100 kA
- Making capacity AC23A 400 V: 2000 A
- Breaking capacity AC23A 400 V: 1600 A
- Mechanical life: 10000 cycles
- Terminal tightening torque (max): 13 Nm
- Operating temperature: -25 to 55 °C
- Storage temperature: -40 to 70 °C
- Max altitude: 3000 m
- IP degree (frontal): IP20
- Pollution degree: 3
What’s Included
- Lovato GE0200B three-pole switch disconnector with BS fuse holder
- Installation and safety instructions
- Manufacturer product datasheet
Applications
- Main isolation and load switching in industrial control panels and switchboards
- Distribution boards requiring AC21/AC22 duty up to 690 V
- Motor load switching within AC23A ratings at 400–690 V
- HVAC, pumping and process equipment isolation and maintenance
Frequently Asked Questions
What fuse type does the GE0200B use?
What are the AC23A ratings at higher voltages?
Is the product compliant with IEC/EN standards?
How is it mounted and what torque applies?
What environmental limits should I follow?
Safety note: Installation must be performed by qualified personnel. Always isolate power, use correctly rated BS fuses, observe specified torque and clearances, and follow IEC/EN 60947 requirements and the provided instructions.
| Manufacturer Part Number | GE0200B |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975175774 |