We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
GE0160P - 3P SWITCH DISCONNECTOR
MPN: GE0160P
Why Choose the GE0160P?
The Lovato GE0160P is a three-pole switch disconnector designed for reliable AC isolation in industrial panels. With an IEC conventional free-air thermal current Ith of 160 A and screw-on plate installation, this compact unit supports AC21A, AC22A and AC23A duties. Rated insulation voltage is 1000 V with 8 kV impulse withstand, and the frontal IP20 degree provides added touch safety during operation and maintenance.
Engineered for performance and longevity, GE0160P delivers up to 90 kW at AC23A 400 V and 75 kW at AC23A 690 V, with mechanical life rated to 30,000 cycles. It offers a 100 kA conditional short-circuit current when protected by a gG160 fuse, 4 Nm max terminal torque, and dependable service from -25 to 55 °C, storage -40 to 70 °C, up to 3000 m, pollution degree 3, per IEC/EN 60947-1/-3.
Key Benefits
- 160 A Ith provides robust isolation and switching capacity for AC circuits.
- AC21A/AC22A/AC23A ratings across 400-690 V enable versatile load switching.
- High insulation strength: Ui 1000 V and Uimp 8 kV for reliability.
- Conditional short-circuit current 100 kA when protected by a gG160 fuse.
- Frontal IP20 degree offers basic touch protection during operation.
- Mechanical life rated to 30,000 cycles for durable service.
- Wide operating range: -25 to 55 °C; altitude up to 3000 m.
- Screw-on plate installation and 4 Nm max terminal tightening torque.
Technical Specification
- Product type designation: GE
- Number of poles: 3
- Operating voltage type: AC
- Ith (IEC): 160 A
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 8 kV
- Operating current Ie AC21A 400 V: 160 A
- Operating current Ie AC21A 500 V: 160 A
- Operating current Ie AC21A 690 V: 160 A
- Operating current Ie AC22A 400 V: 160 A
- Operating current Ie AC22A 500 V: 125 A
- Operating current Ie AC22A 690 V: 125 A
- Operating current Ie AC23A 400 V: 160 A
- Operating current Ie AC23A 500 V: 125 A
- Operating current Ie AC23A 690 V: 80 A
- Power dissipation per pole (max): 4 W
- Rated operational power AC23A 400 V: 90 kW
- Rated operational power AC23A 690 V: 75 kW
- Conditional short-circuit current (rms): 100 kA
- Short-circuit protection fuse: gG160
- Making capacity AC23A 400 V: 1600 A
- Breaking capacity AC23A 400 V: 1280 A
- Mechanical life: 30000 cycles
- Terminal tightening torque (max): 4 Nm
- Operating temperature: -25 to 55 °C
- Storage temperature: -40 to 70 °C
- Max altitude: 3000 m
- IP degree (frontal): IP20
- Pollution degree: 3
What’s Included
- Lovato GE0160P three-pole switch disconnector
- Installation and safety information
Applications
- AC isolation for resistive and mixed loads (AC21A/AC22A duties).
- Switching of motor loads within AC23A current and power ratings.
- Panel main isolator on screw-on plates in control assemblies.
- Use in installations up to 3000 m altitude, pollution degree 3.
- Systems requiring Ui 1000 V insulation and IP20 frontal protection.
Frequently Asked Questions
What is the current rating of the Lovato GE0160P?
How many poles and what operating voltage type does it support?
What are its AC23A operating current ratings?
What short-circuit protection should be used?
Which standards does the GE0160P conform to?
Safety note: Install and service only by qualified personnel. Isolate all supplies before work, use the specified gG160 fuse, observe IP20 frontal limitation, tighten terminals to a maximum of 4 Nm, and operate within the stated ratings and environmental limits.
| Manufacturer Part Number | GE0160P |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975186770 |