We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
GAZ080ET6 - 3P CHANGEOVER SWITCH 80A ENCLOSED
MPN: GAZ080ET6
Why Choose the GAZ080ET6?
The Lovato GAZ080ET6 is a three‑pole line changeover switch I‑0‑II, rated 80 A, supplied in a UL/CSA Type 4/4X non‑metallic enclosure for demanding environments. The compact IP65 frontal protection and 280x220x172mm enclosure suit control panels and distribution boards. With Ui 1000 V and Uimp 8 kV, it delivers dependable isolation and supply selection for AC systems.
Designed for performance, it achieves AC21A and AC22A currents of 80 A up to 690 V, and AC23A of 80 A at 400 V, 63 A at 500 V, and 47 A at 690 V. Making/breaking at AC23A 400 V are 800 A/640 A. Conditional short‑circuit current is 50 kA with gG80 fuse. Mechanical and electrical life reach 30,000 cycles, with operation from −25 to +55 °C.
Key Benefits
- Three-pole I‑0‑II changeover for reliable line selection.
- 80 A Ith and robust AC23A switching performance.
- IP65 frontal protection; UL/CSA Type 4/4X enclosure resists harsh environments.
- High insulation: Ui 1000 V, Uimp 8 kV.
- Strong short-circuit withstand with gG80 fuse to 50 kA.
- Durable design with 30,000 mechanical and electrical cycles.
- Wide cable range, 4–70 mm²; terminals tighten to 5–6 Nm.
Technical Specification
- Product type designation: GAZ
- Number of poles: 3
- Operating voltage type: AC
- Ith (IEC): 80 A
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 8 kV
- Operating current Ie AC21A 400 V: 80 A
- Operating current Ie AC21A 500 V: 80 A
- Operating current Ie AC21A 690 V: 80 A
- Operating current Ie AC22A 400 V: 80 A
- Operating current Ie AC22A 500 V: 80 A
- Operating current Ie AC22A 690 V: 80 A
- Operating current Ie AC23A 400 V: 80 A
- Operating current Ie AC23A 500 V: 63 A
- Operating current Ie AC23A 690 V: 47 A
- Power dissipation per pole (max): 2.6 W
- Rated operational power AC23A 400 V: 45 kW
- Rated operational power AC23A 690 V: 45 kW
- Conditional short-circuit current (rms): 50 kA
- Short-circuit protection fuse: gG80
- Making capacity AC23A 400 V: 800 A
- Breaking capacity AC23A 400 V: 640 A
- Mechanical life: 30000 cycles
- Electrical life AC21A: 30000 cycles
- Terminal tightening torque: 5 to 6 Nm
- Conductor section (IEC): 4 to 70 mm²
- Operating temperature: -25 to +55 °C
- Storage temperature: -40 to +70 °C
- Max altitude: 3000 m
- IP degree (frontal): IP65
- IP degree of protection: IP65
- Pollution degree: 3
What’s Included
- Enclosed three-pole I‑0‑II changeover switch assembly (UL/CSA Type 4/4X)
- Front-mounted selector handle and legend plate fitted
- Non‑metallic enclosure with IP65 frontal protection
- Installation leaflet and fixing hardware
Applications
- Mains–generator supply changeover for commercial premises
- Distribution board line selection and maintenance bypass
- Industrial plant, HVAC and pump circuits within AC23A duty
- OEM control panels and machinery supply switching
- Backup and emergency power transfer equipment
Frequently Asked Questions
What is the current rating and duty performance?
What are the enclosure and ingress protection ratings?
Which standards does this changeover switch comply with?
What cable sizes and terminal torque are supported?
What is the operating temperature and service life?
Safety note: Install and commission only by qualified personnel. Isolate all supplies before work, use a gG80 fuse as specified, and observe the stated torque, conductor sizes, and applicable standards.
| Manufacturer Part Number | GAZ080ET6 |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975209691 |