Danfoss 131N0177 VLT HVAC Drive FC-101 0.75kW Three Phase 380 - 480 VAC IP54
MPN: 131N0177
Alt. SKU: FC-101PK75T4E5AH2XAXXXXSXXXXAXBXCXXXXDX
Why Choose the Danfoss FC‑101 HVAC Basic Drive (Part 131N0177)?
The Danfoss FC‑101 (PK75), part number 131N0177, delivers 0.75 kW / 1 HP three-phase control for HVAC, pump, and compressor applications. It supports 380–480 VAC and comes in an IP54 enclosure (Frame I2). Features include an RFI Class A2 (industrial zone) filter, alpha‑numeric Local Control Panel interface, and a non‑coated PCB. No brake chopper or mains option is included. Ideal for rugged fan and pump installations.
Technical Specifications
| Part Number | 131N0177 |
|---|---|
| Model Code | FC‑101PK75T4E5AH2XAXXXXSXXXXAXBXCXXXXDX |
| Power Rating | 0.75 kW / 1 HP |
| Voltage | Three‑phase 380–480 VAC |
| Enclosure | IP54 chassis (Frame I2, not Type 12) |
| RFI Filter | Class A2 (C3) |
| Brake Chopper | Not included |
| Local Control Panel (LCP) | Included — alpha‑numeric interface |
| PCB Coating | Not coated |
| Net Weight | ≈ 5.3 kg |
| Gross Weight | ≈ 5.9 kg |
| Certifications | CE, UL/cUL, RoHS; UL LZGH2 (A2L refrigerants) |
Frequently Asked Questions
- What does the “XX” suffix mean?
- What RFI/EMC compliance does it have?
- Can I add a logic or display module?
- Is it suitable for multi‑drive use?
- Which certifications apply?
Typical Applications
- IP54-rated fan and pump control in harsh environments
- OEM panel integrations for HVAC/R systems
- Industrial compressor or ventilation setups requiring Class A2 EMC
Key Features
- IP54 rugged chassis ideal for industrial installations
- Integrated RFI Filter Class A2 (C3) with built‑in DC choke
- Alpha-numeric Local Control Panel included for commissioning
- Automatic Energy Optimiser saves ~3–5 % energy during startup and operation
- Compact footprint with no brake chopper or mains module required
Detailed FAQs
The “XX” suffix designates a standard global variant; no optional hardware or software included—core functionality remains consistent across models.
This model includes a built-in RFI filter rated Class A2 (IEC C3), appropriate for industrial environments.
A local alpha-numeric LCP is included. Additional logic or display modules are not required but are available separately if needed.
Yes—the FC 101 family is commonly used in clustered HVAC/BMS installations. Be sure to observe proper EMC layout and spacing for optimal performance.
Fully certified to CE, UL/cUL, and RoHS. UL LZGH2 compliance is included for use with A2L refrigerants under UL 60335‑2‑40 / ‑2‑89.
Trusted by Industry Professionals
“We chose 131N0177 for robust HVAC systems—its IP54 rating and Class A2 filter make commissioning effortless.”
— Controls Engineer, Industrial HVAC OEM
| Manufacturer Part Number | 131N0177 |
|---|---|
| Barcode | 5710107089932 |
| Height | 332mm |
| Width | 115mm |
| Depth | 225mm |
| Brake - Safe-Stop | No brake chopper |
| Coating PCB | Not coated PCB |
| Control Panel | Alpha Numeric LCP |
| Filter | RFI Filter |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP54 |
| KW Rating | 0.75kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT HVAC Drive FC-101 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-101PK75T4E5AH2XAXXXXSXXXXAXBXCXXXXDX |