We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BFK3200A12060 - 3P CONTACTOR 25KVAR 120V 60HZ
MPN: BFK3200A12060
Why Choose the BFK3200A12060?
Engineered by Lovato, the BFK3200A12060 is a contactor for power factor correction with an AC control circuit, designed for reliable switching of capacitor banks. It includes limiting resistors and delivers up to 25 kvar at 400 V. A 3‑pole design with a 120 VAC 60 Hz coil, it mounts by screw or on 35 mm DIN rail.
Built on the BFK32 platform, it offers Ui 690 V, Uimp 6 kV and Ith 56 A, with a mechanical life of 20,000,000 cycles. Operating from −50 to 70 °C up to 3000 m and pollution degree 3, it tightens to 2.5–3 Nm and weighs 400 g. Complies with IEC/EN/BS 60947-1/-4-1, UL and CSA standards.
Key Benefits
- Integrated limiting resistors for smooth capacitor switching and reduced inrush.
- 25 kvar at 400 V delivers dependable power factor correction capacity.
- 120 VAC 60 Hz AC coil for straightforward control integration.
- 3‑pole contactor with screw or 35 mm DIN rail mounting.
- High endurance: 20,000,000 mechanical cycles for long service life.
- Robust insulation: Ui 690 V and Uimp 6 kV withstand transients.
- Wide operating temperature −50 to 70 °C suits harsh environments.
Technical Specification
- Product type designation: BFK32
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 56 A
- Terminal tightening torque: 2.5 to 3 Nm
- Weight: 400 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK32 power factor correction contactor (BFK3200A12060)
- Integrated limiting resistors
- Installation and safety instructions
Applications
- Switching of low‑voltage capacitor banks for power factor correction.
- Industrial power factor correction panels and automation cabinets.
- Commercial building LV distribution PFC systems.
- OEM equipment requiring AC‑controlled capacitor switching.
Frequently Asked Questions
What coil voltage and frequency does the BFK3200A12060 use?
Does this contactor include limiting resistors for capacitor switching?
What is the IEC operational power at 400 V?
How can it be mounted?
Which standards does it conform to?
Safety note: Installation and maintenance must be performed by qualified personnel. Isolate all power sources before work, observe specified torque and environmental limits, and follow applicable standards and instructions.
| Manufacturer Part Number | BFK3200A12060 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975163658 |
| Coil Voltage | 120V |