We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BF9500E024 Lovato contactor 3 pole AC3:95A 55kw 24VAC/DC coil
MPN: BF9500E024
Why Choose the BF9500E024?
Lovato’s BF9500E024 is a robust three‑pole contactor for demanding motor control. With an AC/DC coil rated 20...48 V and AC‑3 performance of 95A (400 V, 55 kW), it delivers dependable switching in industrial panels. AC‑1 Ith is 140 A, with DIN rail 35 mm or screw mounting options to speed installation and simplify upgrades.
Engineered as part of the BF95 series, this contactor carries 1000 V rated insulation (Ui) and 8 kV impulse withstand (Uimp) for reliable dielectric strength. A 15,000,000‑cycle mechanical life supports long service, while a wide -50 to 70 °C operating range and 6–7 Nm terminal tightening torque ensure solid connections in harsh environments.
Key Benefits
- AC/DC coil 20...48 V reduces control circuit complexity.
- Strong AC‑3 rating: 95A at 400 V, up to 55 kW motors.
- High insulation: Ui 1000 V and Uimp 8 kV for reliability.
- Wide -50 to 70 °C operating range suits harsh environments.
- Fast installation via 35 mm DIN rail or screw mounting.
- Long mechanical life of 15,000,000 cycles lowers downtime risk.
- Secure terminations with 6–7 Nm tightening torque.
- Conforms to IEC/EN/BS, UL and CSA standards for assured compliance.
Technical Specification
- Product type designation: BF95
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 1000 V
- Rated impulse withstand voltage Uimp: 8 kV
- Ith (IEC): 140 A
- Terminal tightening torque: 6 to 7 Nm
- Weight: 2060 g
- Mechanical life: 15000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to +80 °C
- Max altitude: 3000 m
What’s Included
- Lovato BF9500E024 three-pole contactor
- Installation and safety leaflet
Applications
- Three-phase motor control up to 55 kW (AC-3, 400 V)
- Resistive load switching to 140 A (AC-1)
- Pumps, fans, compressors and conveyors
- HVAC and building services control panels
Frequently Asked Questions
What coil voltage does the BF9500E024 use?
How can this contactor be mounted?
What are the key current and power ratings?
What environmental limits should I observe?
Which standards does it comply with?
Safety note: Install and service only by qualified personnel. Isolate power before work, follow IEC/EN 60947 practices, apply 6–7 Nm terminal torque, and respect the stated voltage, current and temperature ratings.
| Manufacturer Part Number | BF9500E024 |
|---|---|
| HS Code | 85365080 |
| Manufacturer | Lovato |
| KW Rating | 55kW |
| Number of Poles | 3 Pole |
| Coil Voltage | 24VAC/DC |
| AC3 Amperage | 95A |
| AC1 Amperage | 140A |
| Barcode | 8013975241738 |