131U9851 Danfoss VLT HVAC Drive 4.0KW/5.5HP 380-480VAC IP66
MPN: 131U9851
Alt. SKU: FC-102P4K0T4Z66H2XGXXXXSXXXXAXBXCXXXXDX
Why Choose the 131U9851?
The Danfoss 131U9851 (model code FC-102P4K0T4Z66H2XGXXXXSXXXXAXBXCXXXXDX) is a Variable speed drive (frequency converter) intended for panel installation where accurate motor control, repeatable commissioning, and reliable like-for-like replacement are required.
Configured with Power: (P4K0) 4.0 KW / 5.0 HP, Current: 8.2, Supply: 380 - 480 VAC, Phase: Three phase, Enclosure: IP66 / Type 4X A4 Frame, EMC/RFI: RFI Filter to support correct selection and like-for-like replacements.
Key Benefits
- Variable speed drive (frequency converter) for correct application matching
- Configured with Power: (P4K0) 4.0 KW / 5.0 HP, Current: 8.2, Supply: 380 - 480 VAC, Phase: Three phase, Enclosure: IP66 / Type 4X A4 Frame, EMC/RFI: RFI Filter.
- Suitable for panel installations where reliable commissioning is required.
- SKU and model code shown for procurement and like for like replacements.
Technical Specifications
- Series: 102
- Power Rating: (P4K0) 4.0 KW / 5.0 HP
- Mains Voltage: 380 - 480 VAC
- Phase: Three phase
- Enclosure: IP66 / Type 4X A4 Frame
- RFI Filter: RFI Filter
- Height [mm]: 391,0
- Width w/ no C options [mm]: 200,0
- Depth [mm]: 177,0
- Net weight: 7.64 Kilogram
- EAN: 5710107015061
- A Option: No A Option
- Adaptation A: Standard Cable Entries
- Adaptation B: No adaptation
- B Option: No B Option
- Brake - Safe Stop: No brake chopper
- C Option Software: No software option
- C0 Option MCO: No C0 option
- C1 Option: No C1 option
- Coating PCB: Not coated PCB
- Continuous Current (NO) [A]: 8.2
- D Option: No D option
- Depth with Option A/B [mm]: 177,0
- Frame Size: A4
- Gross weight: 8.376 Kilogram
- Intermittent Current (NO) [A]: 9.02
- LCP: Graphical Loc. Cont. Panel
- Mains Option: No Mains Option
- Modelcode01: FC-102P4K0T4Z66H2XGX
- Modelcode02: XXXSXXXXAXBXCXXXXDX
- Power 110% (NO) [KW]: 4
- Power Loss NO [W]: 124
- Product Group: VLT® HVAC Drive FC-
- Software Language Pack: Standard Language Pack
- Software Release: Latest release std. SW.
- Typecode Part 1: FC-102P4K0T4Z66H2XGX
- Typecode Part 2: XXXSXXXXAXBXCXXXXDX
Frequently Asked Questions
What supply does Danfoss 131U9851 require?
What is the rated power for 131U9851?
What enclosure class is it?
Does it include an EMC/RFI filter?
Where is 131U9851 typically installed?
What does IP20 mean for 131U9851?
| Manufacturer Part Number | 131U9851 |
|---|---|
| Barcode | 5710107015061 |
| Height | 390mm |
| Width | 200mm |
| Depth | 175mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP66 |
| KW Rating | 4kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P4K0T4Z66H2XGXXXXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.