1SFL587002R1311 af305-30-11-13 160kw/305 amp 100-250v 50/60hz-dc ABB Contactor
1SFL587002R1311
Dimensions
Product Net Width: 140.0 mm
Product Net Depth: 180.0 mm
Product Net Height: 225.0 mm
Product Net Weight: 4.640 kg
Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
Rated Operational Current AC-1 (Ie):
(690 V) 55 °C 400 A
(690 V) 40 °C 500 A
(1000 V) 40 °C 375 A
(1000 V) 55 °C 325 A
(690 V) 70 °C 325 A
(1000 V) 70 °C 260 A
Rated Operational Current AC-3 (Ie):
(1000 V) 55 °C 100 A
(220 / 230 / 240 V) 55 °C 305 A
(690 V) 55 °C 290 A
(415 V) 55 °C 305 A
(440 V) 55 °C 305 A
(380 / 400 V) 55 °C 305 A
(500 V) 55 °C 290 A
Rated Operational Power AC-3 (Pe):
(220 / 230 / 240 V) 90 kW
(380 / 400 V) 160 kW
(415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(1000 V) 132 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 500 A
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A
Maximum Electrical Switching Frequency:
AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
Rated Operational Current DC-1 (le):
(110 V) 2 Poles in Series, 40 °C 400 A
(220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-3 (le):
(110 V) 2 Poles in Series, 40 °C 400 A
(220 V) 3 Poles in Series, 40 °C 400 A
Rated Operational Current DC-5 (le):
(110 V) 2 Poles in Series, 40 °C 400 A
(220 V) 3 Poles in Series, 40 °C 400 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 5 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 100 ... 250 V
50 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Holding at Max. Rated Control Circuit Voltage DC 4.5 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Operate Time:
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main Circuit:
Rigid Al-Cable 1 x 185 ... 240 mm²
Flexible 1 x 16 ... 240 mm²
Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit:
Solid 2 x 1 ... 4 mm²
Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²
Stranded 1 x 1 .... 4 mm²
Flexible 1x0.75 ... 2.5 mm²
Flexible with Ferrule 1 x 0.75 ... 2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type: Main Circuit: Bars
Manufacturer | ABB |
---|---|
kW Rating | 160KW |
Inbuilt Aux | 1 N/O, 1 N/C |
Alternative Product SKU | 1SFL587002R1311 |
Manufacturer Part Number | AF305-30-11-13 |