1SFL647001R7011 af1250-30-11 100-250v 50/60hz-dc ABB Contactor
1SFL647001R7011
Dimensions
Product Net Width: 210.0 mm
Product Net Depth: 242.0 mm
Product Net Height: 344.0 mm
Product Net Weight: 15.000 kg
Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A
Rated Operational Current AC-1 (Ie):
(690 V) 55 °C 1040 A
(690 V) 40 °C 1260 A
(1000 V) 40 °C 1260 A
(1000 V) 55 °C 1040 A
(690 V) 70 °C 875 A
(1000 V) 70 °C 875 A
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
Rated Operational Current DC-1 (Ie):
(850 V) 3 Poles in Series, 40 °C 1250 A
(600 V) 3 Poles in Series, 40 °C 1250 A
(220 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-3 (Ie):
(850 V) 3 Poles in Series, 40 °C 1250 A
(600 V) 3 Poles in Series, 40 °C 1250 A
(220 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-5 (Ie):
(850 V) 3 Poles in Series, 40 °C 1250 A
(600 V) 3 Poles in Series, 40 °C 1250 A
(220 V) 3 Poles in Series, 40 °C 1250 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 0.5 million
Maximum Mechanical Switching Frequency: 300 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 100 … 250 V
50 Hz 100 … 250 V
DC Operation 100 … 250 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A
Holding at Max. Rated Control Circuit Voltage DC 5 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
Operate Time:
Between Coil Energization and NO Contact Closing 50 … 120 ms
Between Coil De-energization and NO Contact Opening 53 … 73 ms
Between Coil De-energization and NC Contact Closing 50 … 70 ms
Between Coil Energization and NC Contact Opening 45 … 115 ms
Connecting Capacity Main Circuit: Bar 50 mm
Connecting Capacity Auxiliary Circuit:
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 1x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screw with cable clamp
Terminal Type: Main Circuit: Bars
Manufacturer | ABB |
---|---|
Inbuilt Aux | 1 N/O, 1 N/C |
Alternative Product SKU | 1SFL647001R7011 |
Manufacturer Part Number | AF1250-30-11 100-250V |
Product Lead Time | Please contact us for a delivery time |
Links | Click here for link to ABB website info (opens in new tab) |
ABB AF Contactor Range ABB contactor range can be used to control power circuits up to a level of 690 V AC and 220 V DC. The main benefit of ABB's range of AF products are that only a few coils are needed for different control voltages used in many applications without having to change the coil. |