We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BFK5000A230 - PFC CONTACTOR 40KVAR 230VAC 50/60HZ
MPN: BFK5000A230
Why Choose the BFK5000A230?
Lovato’s BFK5000A230 is a contactor for power factor correction with AC control circuit, engineered for dependable capacitor switching. With a 230VAC 50/60Hz coil and 3‑pole configuration, it delivers up to 40 kvar at 400V per IEC ratings. Integrated limiting resistors support smooth engagement and reduced stress on capacitor banks, helping ensure consistent operation in reactive power compensation applications.
Built for demanding environments, it offers Ui 690 V, Uimp 8 kV and Ith 90 A, with a mechanical life of 15,000,000 cycles. Operating from -50 to 70 °C up to 3000 m altitude, it mounts via screws or 35 mm DIN rail. Conformity with IEC/EN/BS 60947-1/-4-1, UL and CSA standards supports safe, reliable performance in industrial and commercial PFC systems.
Key Benefits
- 40 kvar at 400V IEC rating for robust capacitor bank control.
- 230VAC 50/60Hz coil for straightforward control circuit integration.
- Built-in limiting resistors reduce inrush during capacitor switching.
- 3-pole configuration suited to balanced three-phase applications.
- High insulation ratings: Ui 690 V, Uimp 8 kV.
- Long mechanical life rated at 15,000,000 cycles.
- Wide -50 to 70 °C operating temperature, up to 3000 m altitude.
- Flexible screw or 35 mm DIN rail mounting options.
Technical Specification
- Product type designation: BFK50
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 8 kV
- Ith (IEC): 90 A
- Terminal tightening torque: 4 to 5 Nm
- Weight: 1090 g
- Mechanical life: 15000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK5000A230 contactor unit
- Integrated limiting resistors as standard
- Instruction leaflet
Applications
- Low-voltage capacitor bank switching for power factor correction.
- Automatic power factor correction (APFC) panels and systems.
- Industrial distribution boards and motor control centres with PFC stages.
- Commercial building switchboards requiring reactive power compensation.
Frequently Asked Questions
What is the coil voltage and frequency of the BFK5000A230?
What capacitor power can it switch at 400 V?
How many poles does this contactor have?
How can it be mounted in a panel?
Which standards does it conform to?
Safety note: Installation and commissioning should be performed by qualified personnel. Isolate all power sources before work and follow manufacturer instructions and applicable IEC/EN/BS, UL and CSA standards.
| Manufacturer Part Number | BFK5000A230 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975224489 |
| Coil Voltage | 230VAC |