BFK3800A230 - 3P CONTACTOR 30KVAR 230V 50/60HZ
MPN: BFK3800A230
Why Choose the BFK3800A230?
Lovato's BFK3800A230 contactor for power factor correction with an AC control circuit is engineered for dependable capacitor switching in low-voltage systems. Integrating limiting resistors and a 230VAC 50/60Hz coil, it delivers up to 30kvar at 400V across three poles. With versatile screw or 35mm DIN-rail mounting, the BFK3800A230 suits space-conscious control panels, upgrades, and new builds where efficient power factor management is essential.
Built to last and perform, this BFK38 series unit offers Ui 690 V and Uimp 6 kV, with Ith 56 A for demanding duty. A 20,000,000-cycle mechanical life, Pollution Degree 3 rating, and operation from -50 to 70 °C provide resilience. It also meets IEC/EN/BS 60947-1/-4-1, UL 60947-1/-4-1 and CSA C22.2 requirements for assured compliance.
Key Benefits
- Dedicated for power factor correction with integrated limiting resistors.
- 30kvar at 400V for robust three-phase capacitor switching.
- 230VAC 50/60Hz coil for common control supplies.
- Three-pole configuration with high 56 A thermal current rating.
- High dielectric strength: Ui 690 V, Uimp 6 kV.
- Flexible screw or 35 mm DIN-rail mounting.
- Wide operating range from -50 °C to 70 °C.
Technical Specification
- Product type designation: BFK38
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 56 A
- Terminal tightening torque: 2.5 to 3 Nm
- Weight: 400 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK3800A230 contactor assembly
- Integrated limiting resistors
- Installation and safety information
- Protective packaging for transit
Applications
- Switching three-phase capacitor banks for power factor correction
- Power factor correction panels up to 30kvar at 400 V
- Industrial control cabinets with AC control circuits
- DIN-rail or screw-mounted control assemblies
- Installations up to 3000 m altitude and wide ambient temperatures
Frequently Asked Questions
What is the coil voltage and frequency?
What is the maximum IEC operational power at 400 V?
How is the contactor mounted?
What is the mechanical life of this unit?
Which standards does this product comply with?
Safety note: Only qualified personnel should install and commission this device. Isolate power and allow connected capacitors to discharge fully before work, following applicable standards and local regulations.
| Manufacturer Part Number | BFK3800A230 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975164365 |
| Coil Voltage | 230V |