We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BFK2600A02460 - 3P CONTACTOR 20KVAR 24V 60HZ
MPN: BFK2600A02460
Why Choose the BFK2600A02460?
Engineered by Lovato, the BFK2600A02460 is a contactor for power factor correction with AC control circuit, supplied with integrated limiting resistors. This 3‑pole unit features an AC coil rated 24 VAC 60 Hz and delivers IEC operational power of 20 kvar at 400 V. Flexible installation is supported via screw fixing or 35 mm DIN rail mounting.
Built on the BFK26 designation, it offers Ui 690 V, Uimp 6 kV and Ith 45 A, with a mechanical life of 20,000,000 cycles. Rated for -50 to 70 °C operation, storage -60 to 80 °C and up to 3000 m altitude, it complies with IEC/EN/BS 60947-1/-4-1, plus UL and CSA standards.
Key Benefits
- Purpose-built for power factor correction with AC control circuit.
- 24 VAC 60 Hz coil for straightforward control integration.
- Rated 20 kvar at 400 V under IEC conditions.
- Three-pole design with screw or 35 mm DIN rail mounting.
- High insulation ratings: Ui 690 V and Uimp 6 kV.
- Robust Ith 45 A and 20,000,000-cycle mechanical life.
- Wide -50 to 70 °C operation; altitude capability up to 3000 m.
- Includes limiting resistors for power factor correction applications.
Technical Specification
- Product type designation: BFK26
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 45 A
- Terminal tightening torque: 2.5 to 3 Nm
- Weight: 400 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK2600A02460 contactor assembly
- Integrated limiting resistors for power factor correction
- 24 VAC 60 Hz control coil pre-fitted
- Installation and safety information
Applications
- Low-voltage power factor correction capacitor switching up to 20 kvar at 400 V
- Industrial power factor correction banks and automatic capacitor stages
- Control panels requiring a 24 VAC 60 Hz coil
- Switchboards using screw-fixed or 35 mm DIN rail mounted contactors
Frequently Asked Questions
What coil voltage and frequency does this contactor use?
What is the IEC operational power at 400 V?
How can this contactor be mounted?
Which standards does it comply with?
What is the operating temperature range?
Safety note: Install and commission only by qualified personnel. Isolate all power sources, verify 24 VAC 60 Hz coil supply, observe specified tightening torque and environmental limits, and follow applicable standards.
| Manufacturer Part Number | BFK2600A02460 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975163429 |
| Coil Voltage | 24V |