We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
BFK1210A23060 - 3P CONTACTOR 12 5KVAR 230V 60HZ
MPN: BFK1210A23060
Why Choose the BFK1210A23060?
The Lovato BFK1210A23060 is a contactor for power factor correction with an AC control circuit, designed for reliable capacitor switching. Rated at 12.5 kvar at 400 V and fitted with a 230 VAC 60 Hz coil, it features a 3-pole configuration with 1NO auxiliary contact. Integrated limiting resistors help reduce inrush. Flexible screw or 35 mm DIN rail mounting simplifies panel installation.
Built for demanding environments, the BFK12 series offers Ui 690 V and 6 kV impulse withstand, with Ith 28 A for robust performance. A mechanical life of 20,000,000 cycles and an operating range from -50 to 70 °C support long service. Rated Pollution Degree 3 and suitable up to 3000 m altitude, it conforms to IEC/EN/BS 60947 and related UL/CSA standards.
Key Benefits
- Optimised for power factor correction with integrated limiting resistors.
- 12.5 kvar IEC operational power at 400 V.
- 230 VAC 60 Hz coil for AC control circuits.
- 3-pole main contacts plus 1NO auxiliary contact.
- Screw or 35 mm DIN rail mounting for easy installation.
- High dielectric performance: Ui 690 V, Uimp 6 kV.
- Wide operating range and long 20,000,000-cycle mechanical life.
Technical Specification
- Product type designation: BFK12
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 28 A
- Terminal tightening torque: 1.5 to 1.8 Nm
- Weight: 418 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BFK1210A23060 contactor (BFK12 series)
- Integrated limiting resistors for capacitor switching
- Basic installation and safety information from the manufacturer
Applications
- Power factor correction capacitor bank switching
- Automatic PFC stages in industrial and commercial panels
- Low-voltage electrical distribution requiring reactive power compensation
- AC control circuits with 230 VAC 60 Hz coil supply
Frequently Asked Questions
What is the coil voltage and frequency?
What is the operational power rating at 400 V?
Does this contactor include limiting resistors?
How is it mounted in the panel?
Which standards does it conform to?
Safety note: Install and service only by qualified personnel. Isolate power before work, observe the specified terminal torque (1.5–1.8 Nm), and ensure operation within the stated environmental limits and standards.
| Manufacturer Part Number | BFK1210A23060 |
|---|---|
| Manufacturer | Lovato |
| Barcode | 8013975163221 |
| Coil Voltage | 230V |