Why Choose the BF18T2A02460?
Designed for dependable switching in industrial control panels, the Lovato BF18 four-pole contactor BF18T2A02460 pairs a 24VAC 60Hz coil with 2NO and 2NC contacts. It is rated 32A AC1 and 18A/7.5 kW AC3 at 400 V to cover common motor and resistive loads. Screw or 35 mm DIN rail mounting makes installation straightforward, with compliance to IEC/EN/BS 60947 standards for UK-spec control gear.
Engineered for long service life, the device provides Ui 690 V insulation and 6 kV impulse withstand, with a mechanical life of 20,000,000 cycles. Operating from -50 to 70 °C and up to 3000 m altitude, it fits robust panel designs. Terminals tighten to 1.5–1.8 Nm, while UL/CSA ratings include 10 HP at 480 V. Pollution degree 3 construction supports consistent performance.
Key Benefits
- 32 A AC1 rating for reliable resistive load switching.
- 18 A/7.5 kW AC3 at 400 V for motor applications.
- 24 VAC 60 Hz coil suits mainstream control voltages.
- Four-pole, 2NO + 2NC layout increases wiring flexibility.
- Screw or 35 mm DIN rail mounting speeds installation.
- High insulation margins: Ui 690 V and Uimp 6 kV.
- Wide operating range: -50 to 70 °C; altitude to 3000 m.
Technical Specification
- Product type designation: BF18
- Number of poles: 4
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 32 A
- Terminal tightening torque: 1.5 to 1.8 Nm
- Weight: 356 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BF18T2A02460 four-pole contactor
- Manufacturer datasheet (downloadable)
- Packaging and documentation as supplied by Lovato
Applications
- AC1 resistive load switching up to 32 A
- AC3 motor starting at 400 V up to 18 A / 7.5 kW
- Control panels using 35 mm DIN rail or screw mounting
- UL/CSA installations requiring up to 10 HP at 480 V
- Industrial environments within -50 to 70 °C, up to 3000 m
Frequently Asked Questions
What is the coil voltage and frequency?
How many poles and what contact arrangement does it have?
What are the AC1 and AC3 ratings?
Can this contactor be mounted on DIN rail?
Which standards does it comply with?
Safety note: Installation and servicing must be carried out by qualified personnel. Isolate power before work, observe the stated ratings and temperature limits, tighten terminals to 1.5–1.8 Nm, and install to applicable standards.
| Manufacturer Part Number | BF18T2A02460 |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975162101 |
| Coil Voltage | 24V |