Why Choose the BF1210A12060?
The Lovato BF1210A12060 is a robust three-pole contactor designed for dependable motor and load switching. With an AC-3 rating of 12 A at 400 V (5.7 kW), a 120 VAC 60 Hz coil, and a built-in 1NO auxiliary contact, this BF12 series device delivers reliable performance. It suits screw fixing or 35 mm DIN rail mounting, helping panel builders streamline installations.
Engineered to international standards, the BF1210A12060 offers 690 V rated insulation, 6 kV impulse withstand, and 28 A Ith for AC-1 loads. A mechanical life of 20,000,000 cycles and -50 to 70 °C operating range support demanding environments up to 3000 m altitude. Conforms to IEC/EN/BS 60947 and UL/CSA standards, with 1.5 to 1.8 Nm terminal torque and 7.5 HP at 480 V.
Key Benefits
- AC-3 motor duty rating: 12 A / 5.7 kW at 400 V.
- Wide AC-1 capacity with 28 A thermal current Ith.
- Reliable operation; 20,000,000 mechanical cycles for long service life.
- Safe insulation: Ui 690 V and 6 kV impulse withstand.
- Flexible fitting via screw mounting or 35 mm DIN rail.
- Built-in 1NO auxiliary contact for straightforward control integration.
- Operates from -50 to 70 °C, suitable for varied environments.
Technical Specification
- Product type designation: BF12
- Number of poles: 3
- Rated insulation voltage Ui (IEC/EN): 690 V
- Rated impulse withstand voltage Uimp: 6 kV
- Ith (IEC): 28 A
- Terminal tightening torque: 1.5 to 1.8 Nm
- Weight: 359 g
- Mechanical life: 20000000 cycles
- Operating temperature: -50 to 70 °C
- Storage temperature: -60 to 80 °C
- Max altitude: 3000 m
- Pollution degree: 3
What’s Included
- Lovato BF1210A12060 three-pole contactor
- Integrated 1NO auxiliary contact
- Screw terminal connections ready for wiring
- DIN rail or screw mounting capability
- Manufacturer datasheet (download)
Applications
- Motor starters up to 5.7 kW at 400 V AC-3
- Switching of AC-1 loads up to 28 A
- Control panels requiring 120 V AC 60 Hz coil
- OEM machinery complying with IEC/EN 60947-4-1
- HVAC, pumps and fans using three-pole contactors
Frequently Asked Questions
What is the coil voltage and frequency?
How many poles and auxiliary contacts are included?
What are the mounting options?
What is the AC-3 motor rating at 400 V?
What environmental and endurance ratings does it have?
Safety note: Install and commission only by qualified personnel. Always isolate the supply before wiring, observe the 1.5 to 1.8 Nm terminal torque, and operate within the stated ratings and standards.
| Manufacturer Part Number | BF1210A12060 |
|---|---|
| Manufacturer | Lovato |
| HS Code | 85365080 |
| Barcode | 8013975165164 |
| Coil Voltage | 120V |