AS09-30-10-20 24V50/60HZ Contactor
MPN: 1SBL101001R2010
Alt. SKU: AS09-30-10-20
Why Choose the AS09-30-10-20 [1SBL101001R2010]
The AS09 contactors are designed primarily for controlling three-phase motors and power circuits up to 690 V AC or 220 V DC. Suitable for non-inductive or lightly inductive loads, these 1-stack, 3-pole block-type contactors provide reliable switching performance. Each unit features three main poles and one built-in auxiliary contact, with additional front-mounted auxiliary contact blocks available. These mechanically linked auxiliary contacts comply with Annex L of IEC 60947-5-1, while the normally closed mirror contacts meet the requirements of Annex F of IEC 60947-4-1. The control circuit operates on AC using a laminated magnetic coil for enhanced durability. A comprehensive range of accessories is offered to support various installation and application needs.
Technical Specification
- Function: Controls 3-phase motors and power circuits up to 690 V AC or 220 V DC.
- Main Contacts: 3 NO (Normally Open) contacts.
- Auxiliary Contacts: 1 NO built-in auxiliary contact.
- Rated Operational Voltage: 690 V AC main and auxiliary circuits.
- Rated Operational Current (AC-1): 22 A at 40 °C.
- Rated Operational Current (AC-3): 9 A at 415 V, 60 °C.
- Rated Insulation Voltage (Ui): 690 V (IEC and VDE standards), 600 V (UL/CSA).
- Rated Impulse Withstand Voltage (Uimp): 6 kV (auxiliary circuit).
- Degree of Protection: IP20 for main, auxiliary and coil terminals.
- Terminal Type and Size: Screw terminals; flexible up to 2.5 mm², rigid up to 4 mm².
- Mounting: Fits TH35-15 and TH35-7.5 DIN rails (IEC 60715).
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the primary function of the AS09 contactor?
What types of loads can the AS09 contactor control?
What is the rated operational current for the AS09 contactor?
What is the degree of protection for the AS09 contactor?
What type of mounting is compatible with the AS09 contactor?
What is the maximum cable capacity for the terminals?
Are there any standards or approvals for the AS09 contactor?
| Manufacturer Part Number | 1SBL101001R2010 |
|---|---|
| HS Code | 85365080 |
| Height | 68mm |
| Width | 45mm |
| Depth | 72.5mm |
| Manufacturer | ABB |
| Country of Manufacture | China |
| Alternative Product SKU | AS09-30-10-20 |
| Packed Quantity | 1 |
| Barcode | 3471523032200 |