abb softstarter PSTX470-600-70 pstx (600v) range 470 amp
MPN: 1SFA898116R7000
Alt. SKU: PSTX470-600-70
Why Choose the PSTX470-600-70 [1SFA898116R7000]
The softstarter PSTX470-600-70 has a rated maximum operational current of 470 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.
Technical Specification
- Function: Soft starter with three-phase voltage and torque ramp control, including features like jog, braking, sequence start, and emergency pump mode.
- Rated Operational Voltage: 208 to 600 V AC.
- Rated Operational Current: 470 A inline connection; 814 A inside delta connection.
- Control Supply Voltage: 100 to 250 V AC at 50/60 Hz.
- Terminal Type and Size: Main circuit bars with 8.5 mm hole diameter; control circuit wiring up to 2.5 mm² rigid conductors.
- Protection Rating: Main terminals IP00; detachable full graphic display IP66 with 4x outdoor rating.
- Overload Protection: Built-in electronic overload with adjustable current limit and kickstart functions.
- Communication Options: Modbus RTU, Modbus TCP, Ethernet-IP, EtherCAT, Profibus, Profinet, CANopen, DeviceNet, BACnet-IP and MSTP.
- Mechanical Data: Weight 25 kg; tightening torque 35 N·m for main circuit.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum operational current for the PSTX470-600-70?
What is the operating voltage range for this soft starter?
What control voltage is required for the PSTX470-600-70?
What communication protocols are supported by the PSTX?
What types of motors is the PSTX suitable for?
What is the protection rating of the detachable display?
Is there any overload protection feature in the PSTX?
| Manufacturer Part Number | 1SFA898116R7000 |
|---|---|
| Barcode | 7320500508954 |
| Max Rated Current | 470 Amps |
| Motor Power (kW) at 400V | 250Kw |
| Motor Power (kW) at 500V | 315Kw |
| KW Rating | 250kW |
| HS Code | 85371098 |
| Country of Manufacture | Sweden |
| Manufacturer | ABB |
| Alternative Product SKU | PSTX470-600-70 |