We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
abb softstarter PSR16-600-70 110-240vac control voltage psr range 16 amp
MPN: 1SFA896107R7000
Alt. SKU: PSR16-600-70
Why Choose the PSR16-600-70 [1SFA896107R7000]
The softstarter PSR16-600-70 has a rated maximum operational current of 16 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
Technical Specification
- Function: Soft start and stop with voltage ramp.
- Rated Operational Voltage: 208 to 600 V AC.
- Rated Operational Current: 16 A.
- Control Supply Voltage: 100 to 240 V AC, 50/60 Hz.
- Run Signal Relay: Normally open (NO) relay output.
- Degree of Protection: IP20.
- Terminal Type: Screw terminals.
- Terminal Connecting Capacity: 0.75 to 2.5 mm² rigid cables.
- Ramp Time Setting: Adjustable 0 to 20 seconds start and stop.
- Maximum Start Capacity: 4 times rated current for 6 seconds.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum operational current of the PSR16-600-70?
What is the operating voltage range for this softstarter?
What type of motors is the PSR16-600-70 suitable for?
How can I adjust the start and stop ramp time?
What is the terminal connecting capacity for this softstarter?
Can the PSR16-600-70 be used with a manual motor starter?
What degree of protection does the PSR16-600-70 have?
| Manufacturer Part Number | 1SFA896107R7000 |
|---|---|
| Barcode | 7320500338261 |
| Max Rated Current | 16 Amps |
| Motor Power (kW) at 400V | 7.5Kw |
| Motor Power (kW) at 500V | 7.5Kw |
| KW Rating | 7.5kW |
| HS Code | 85371091 |
| Country of Manufacture | China |
| Manufacturer | ABB |
| Alternative Product SKU | PSR16-600-70 |