Why Choose the PSE300-600-70 [1SFA897114R7000]

Softstarter PSE300-600-70 for max 600V main voltage and 100 - 250V 50/60Hz control supply voltage.

Technical Specification

  • Function: Softstarter for motor starting and overload protection.
  • Rated Operational Voltage: 208 to 600 V AC.
  • Rated Operational Current: 300 A.
  • Rated Control Supply Voltage: 100 to 250 V AC, 50/60 Hz.
  • Starting Capacity: 4 × Ie for 10 seconds.
  • Ramp Time: Adjustable 1 to 30 seconds.
  • Degree of Protection: Main terminals IP00 (IEC 60529).
  • Terminal Type and Size: Main circuit bars, hole diameter 10.2 mm, width 20 mm, thickness 5 mm.
  • Tightening Torque: Main circuit 28 N·m, control and supply circuits 0.5 N·m.
  • Integrated Protection: Built-in electronic overload protection with signal relays for run, bypass, fault, and overload.

Trusted By Customers Worldwide

"Specified by UK panel builders for dependable control." Controls Engineer, UK

Frequently Asked Questions

What is the maximum operational voltage for the PSE300-600-70 softstarter?
The maximum operational voltage is 600V AC.
What is the rated operational current of this softstarter?
The rated operational current is 300 A.
What control supply voltage range does the PSE300-600-70 support?
It supports a control supply voltage range of 100 to 250 V AC, 50/60 Hz.
What is the adjustable ramp time for motor starting?
The ramp time is adjustable from 1 to 30 seconds.
What type of terminals does the softstarter use?
The softstarter uses main circuit bars with a hole diameter of 10.2 mm, width of 20 mm, and thickness of 5 mm.
What is the degree of protection for the main terminals?
The degree of protection for the main terminals is IP00 (IEC 60529).
Does the PSE300-600-70 have built-in protection features?
Yes, it has built-in electronic overload protection with signal relays for run, bypass, fault, and overload.
More Information
Manufacturer Part Number 1SFA897114R7000
Barcode 7320500400722
Max Rated Current 300 Amps
Motor Power (kW) at 400V 160Kw
Motor Power (kW) at 500V 200Kw
KW Rating 160kW
Manufacturer ABB
Write Your Own Review
You're reviewing:abb softstarter PSE300-600-70 pse range 300 amp