ABB s203-z50na mcb s200p 4p z type 50amp
MPN: 2CDS253103R0578
Alt. SKU: S203-Z50NA
Why Choose the S203-Z50NA [2CDS253103R0578]
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical Specification
- Function: 3-pole miniature circuit breaker with delayed thermal and electromechanical short circuit tripping.
- Voltage Ratings: 230/400/440 V AC, 110 V DC.
- Current Rating: Up to 63 A (this model specific rating not explicitly given; assume included in range).
- Breaking Capacity: Ultimate up to 20 kA at 230 V AC; 10 kA at 400/440 V AC.
- Contact Configuration: 3P+N with neutral terminals on right.
- Terminal Type and Capacity: Failsafe, bi-directional screw terminals; supports 0.75–35 mm² flexible and rigid conductors, busbar up to 10×10 mm².
- Electrical Endurance: 10,000 AC operating cycles.
- Mechanical Endurance: 20,000 cycles.
- Dielectric Test Voltage: 2 kV at 50/60 Hz for 1 minute.
- Actuator: Toggle type, black insulation, sealable with red ON/green OFF indication.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What types of tripping mechanisms do the S200 miniature circuit breakers use?
What is the maximum breaking capacity of the S200 circuit breakers?
What is the current rating range for the S200 series?
What conductor sizes can be accommodated by the terminals?
Can auxiliary contacts be mounted on the S200 circuit breakers?
What are the voltage ratings for the S200 circuit breakers?
Are the S200 circuit breakers compliant with any standards?
| Manufacturer Part Number | 2CDS253103R0578 |
|---|---|
| Amperage | 50A |
| Number of Poles | 4 Pole |
| HS Code | 85362010 |
| Country of Manufacture | Germany |
| Manufacturer | ABB |
| Alternative Product SKU | S203-Z50NA |
| Barcode | 4016779552141 |