ABB s203-d1.6na mcb s200p 4p d type 1.6amp
MPN: 2CDS253103R0971
Alt. SKU: S203-D1.6NA
Why Choose the S203-D1.6NA [2CDS253103R0971]
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical Specification
- Function: Current limiting miniature circuit breaker with thermal and electromechanic trip for overload and short circuit protection.
- Rated Current: Up to 63 A.
- Voltage Ratings: 230/400/440 V AC.
- Contact Configuration: 3P+N with neutral terminal on right.
- Breaking Capacity: Ultimate up to 20 kA at 230 V AC, 10 kA at 400/440 V AC; Service up to 15 kA at 230 V AC, 7.5 kA at 400/440 V AC.
- Terminal Type: Failsafe bi-directional cylinder-lift screw terminals.
- Connecting Capacity: Busbar 10/10 mm²; flexible cables 0.75–25 mm²; rigid cables 0.75–35 mm².
- Electrical Endurance: 20,000 AC cycles.
- Mechanical Endurance: 20,000 operation cycles.
- Insulation & Test Voltage: Dielectric test voltage 2 kV at 50/60 Hz for 1 minute.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum rated current for the S200 miniature circuit breakers?
What types of tripping mechanisms are used in the S200 circuit breakers?
What is the breaking capacity of the S200 circuit breakers?
Can auxiliary contacts be mounted on the S200 circuit breakers?
What is the terminal type used in the S200 circuit breakers?
What is the connecting capacity for cables on the S200 circuit breakers?
Are the S200 circuit breakers compliant with any standards?
| Manufacturer Part Number | 2CDS253103R0971 |
|---|---|
| Amperage | 1.6A |
| Number of Poles | 4 Pole |
| Manufacturer | ABB |
| Alternative Product SKU | S203-D1.6NA |
| Barcode | 4016779532785 |
| Product Lead Time | Delivery 7/10 Days |