We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
ABB s202m-z6 mcb s200m 2 pole z type 6amp
MPN: 2CDS272001R0378
Alt. SKU: S202M-Z6
Why Choose the S202M-Z6 [2CDS272001R0378]
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.
Technical Specification
- Function: Two tripping mechanisms - delayed thermal for overload and electromechanic for short circuit protection.
- Voltage and Current Ratings: Rated currents up to 63A; breaking capacity up to 25 kA at 230 V AC and 15 kA at 400/440 V AC.
- Contact Configuration: 2 poles (2P) protected and total.
- Insulation and Impulse Ratings: Dielectric test voltage 2 kV (50/60 Hz, 1 min); energy limiting class 3.
- Terminal Type and Size Range: Screw terminals with failsafe bi-directional cylinder-lift; suitable for flexible 0.75–25 mm² and rigid 0.75–35 mm² conductors.
- Mechanical Durability: 20,000 operation cycles.
- Contact Position Indication: Red ON / Green OFF.
- Actuator: Toggle type, black insulation, sealable, marked I/O.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What are the tripping mechanisms used in the S200M miniature circuit breakers?
What is the maximum breaking capacity of the S200M circuit breakers?
What is the rated current range for the S200M circuit breakers?
Can auxiliary contacts be mounted on the S200M circuit breakers?
What conductor sizes are compatible with the S200M circuit breakers?
What standards do the S200M circuit breakers comply with?
| Manufacturer Part Number | 2CDS272001R0378 |
|---|---|
| Amperage | 3A |
| Number of Poles | 2 Pole |
| HS Code | 85362010 |
| Country of Manufacture | Germany |
| Manufacturer | ABB |
| Alternative Product SKU | S202M-Z6 |
| Barcode | 4016779600651 |