System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical Specification
- Function: Miniature circuit breaker with thermal and electromechanical tripping for overload and short circuit protection.
- Voltage Ratings: Up to 480Y/277 V AC and 110 V DC.
- Current Rating: 50 A rated current, 2 poles (2P) configuration.
- Breaking Capacity: Rated ultimate short-circuit breaking capacity up to 20 kA (230 V AC); rated service breaking capacity 15 kA (230 V AC).
- Contact Position Indication: Red ON / Green OFF.
- Terminal Type: Failsafe bi-directional screw terminals.
- Connecting Capacity: Flexible cables 0.75–25 mm², rigid cables up to 35 mm², busbar 10/10 mm².
- Mechanical Endurance: 20,000 cycles; Electrical Endurance: 10,000 AC cycles.
- Insulation and Impulse Rating: Dielectric test voltage of 2 kV at 50/60 Hz for 1 minute.
- Tightening Torque: 2.8 N·m (18 in·lb UL/CSA).
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the function of the System pro M compact S200 miniature circuit breakers?
What are the available configurations for the S200 MCBs?
What is the maximum breaking capacity of the S200 MCBs?
What is the cable capacity for the S200 MCBs?
Are the S200 MCBs compliant with any standards?
What is the mechanical and electrical endurance of the S200 MCBs?
Can auxiliary contacts be mounted on the S200 MCBs?