Why Choose the S201M-C63 [2CDS271001R0634]
System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space.
Technical Specification
- Function: Current limiting miniature circuit breaker with thermal and electromechanical tripping for overload and short circuit protection.
- Rated Current: Up to 63 A.
- Voltage Ratings: 230/400 V AC, 60 V DC maximum operating voltage (UL/CSA).
- Breaking Capacity: Up to 25 kA (133 V AC), 15 kA (230/400 V AC); UL interrupting rating 6 kA (277 V AC) and 10 kA (60 V DC).
- Contact Configuration: 1 pole (1P) with toggle actuator and red ON/green OFF indication.
- Terminal Type: Failsafe bi-directional screw terminals; connects rigid and flexible cables from 0.75 to 35 mm², busbar up to 10 mm².
- Durability: Mechanical endurance of 20,000 cycles and electrical endurance of 10,000 AC cycles.
- Insulation and Impulse Withstand: Dielectric test voltage 2 kV at 50/60 Hz for 1 minute; Energy Limiting Class 3.
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum rated current for the S200M miniature circuit breakers?
What types of tripping mechanisms are used in the S200M circuit breakers?
What is the breaking capacity of the S200M circuit breakers?
What cable sizes can be connected to the S200M circuit breakers?
Can auxiliary contacts be mounted on the S200M circuit breakers?
What standards do the S200M circuit breakers comply with?
| Manufacturer Part Number | 2CDS271001R0634 |
|---|---|
| Amperage | 63A |
| Number of Poles | 1 Pole |
| Trip Curve Type | Type B 10KA |
| HS Code | 85362010 |
| Country of Manufacture | Germany |
| Manufacturer | ABB |
| Alternative Product SKU | S201M-C63 |
| Barcode | 4016779543941 |