We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
ABB s201-b6 sp mcb b6a 6ka
MPN: 2CDS251001R0065
Alt. SKU: S201-B6
Why Choose the S201-B6 [2CDS251001R0065]
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Technical Specification
- Function: Miniature circuit breaker with thermal and electromechanical tripping for overload and short-circuit protection.
- Rated Current: Up to 63 A.
- Rated Ultimate Short-Circuit Breaking Capacity: Up to 20 kA at 133 V AC, 10 kA at 230/400 V AC.
- Voltage Rating: Up to 480Y/277 V AC and 60 V DC (UL/CSA rated).
- Contact Configuration: Single pole (1P) available.
- Terminal Type and Capacity: Screw terminals; accepts flexible and rigid conductors from 0.75 to 35 mm² and busbars 10/10 mm².
- Electrical and Mechanical Endurance: 20,000 AC cycles and 20,000 mechanical cycles.
- Actuator: Toggle type with red (ON) / green (OFF) indication; sealable.
- Dielectric Test Voltage: 2 kV at 50/60 Hz for 1 minute.
- Tightening Torque: 2.8 N·m (18 in·lb UL/CSA).
Trusted By Customers Worldwide
"Specified by UK panel builders for dependable control." Controls Engineer, UK
Frequently Asked Questions
What is the maximum rated current for the S200 miniature circuit breakers?
What types of tripping mechanisms do the S200 circuit breakers use?
What is the breaking capacity of the S200 circuit breakers?
What conductor sizes can be accommodated by the S200 circuit breakers?
Can auxiliary contacts be mounted on the S200 circuit breakers?
What is the dielectric test voltage for the S200 circuit breakers?
What standards do the S200 circuit breakers comply with?
| Manufacturer Part Number | 2CDS251001R0065 |
|---|---|
| Amperage | 6A |
| Number of Poles | 1 Pole |
| Trip Curve Type | Type B 10KA |
| Manufacturer | ABB |
| Alternative Product SKU | S201-B6 |
| Barcode | 4016779464901 |
| Product Lead Time | Estimated delivery time 3-4 days |