Why Choose the ABB F204 A-25/0.03 Residual Current Circuit Breaker?

The ABB F204 A-25/0.03 is a high-quality 4 pole residual current circuit breaker (RCCB) designed to provide dependable protection against earth leakage faults in commercial, industrial and infrastructure electrical installations. As part of the trusted ABB F200 Series, it helps protect people and electrical systems by disconnecting the supply when residual fault current is detected.

Featuring a 25 A rated current and a 30 mA rated residual operating current, this RCCB is suitable for three-phase distribution systems where personnel protection and reliable earth fault detection are required. The Type A tripping characteristic detects alternating sinusoidal residual currents and pulsating DC residual currents, making it suitable for many modern electrical installations.

The F204 A-25/0.03 is designed for DIN rail mounting inside distribution boards, switchgear assemblies and control panels. Its compact modular design, screw terminal connections and ABB engineering quality make it a dependable choice for professional electrical installations.

Key Advantages

  • Reliable 4 pole RCCB for commercial and industrial installations.
  • 25 A rated current for three-phase electrical distribution circuits.
  • 30 mA residual operating current for personnel and earth fault protection.
  • Type A protection for AC and pulsating DC residual currents.
  • Compact DIN rail mounting for distribution boards and control panels.
  • ABB F200 Series quality with dependable long-term performance.

Key Features

  • ABB F200 Series RCCB.
  • 25 A rated current.
  • 30 mA rated residual operating current.
  • Type A residual current detection.
  • 4 pole configuration.
  • 230 / 400 V AC rated operational voltage.
  • 50 / 60 Hz operation.
  • Instantaneous tripping characteristic.
  • DIN rail mounting.
  • Screw terminal connections.

Technical Specifications

  • Manufacturer: ABB
  • Series: F200 RCCB Series
  • Model: F204 A-25/0.03
  • Product ID: 2CSF204101R1250
  • Product type: Residual Current Circuit Breaker (RCCB)
  • Rated current: 25 A
  • Rated residual operating current: 30 mA
  • Residual current type: Type A
  • Rated operational voltage: 230 / 400 V AC
  • Rated insulation voltage: 500 V
  • Rated impulse withstand voltage: 4 kV
  • Frequency: 50 / 60 Hz
  • Number of poles: 4
  • Operating characteristic: Instantaneous
  • Rated conditional short-circuit current: 10 kA
  • Protection rating: IP2X
  • Mounting type: DIN rail
  • Mounting position: Any
  • Dimensions (H × W × D): 85 × 70 × 69 mm
  • Weight: approx. 0.36 kg
  • Standards: IEC/EN 61008

Reliable Earth Leakage Protection

Residual current circuit breakers continuously monitor the balance between outgoing and returning current. If an earth leakage fault occurs, the RCCB disconnects the circuit quickly, helping protect people and equipment while reducing the risks associated with insulation breakdown and fault currents to earth.

The ABB F204 A-25/0.03 provides Type A residual current detection, making it suitable for installations with equipment that may produce pulsating DC fault currents. This makes it a practical choice for modern commercial and industrial electrical systems.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial switchgear assemblies.
  • Three-phase power distribution systems.
  • Manufacturing and processing facilities.
  • Infrastructure and public building installations.
  • Electrical panels requiring Type A residual current protection.

Frequently Asked Questions

What is the ABB F204 A-25/0.03 used for?

It provides residual current protection by disconnecting the circuit when earth leakage current is detected, helping protect people, equipment and electrical installations.

What does the 25 A rating mean?

The 25 A rating indicates the maximum continuous current the RCCB is designed to carry under normal operating conditions.

What does the 30 mA sensitivity provide?

The 30 mA residual operating current is commonly used for personnel protection in electrical installations where a high level of earth leakage sensitivity is required.

What does Type A mean on this RCCB?

Type A means the device is designed to detect alternating sinusoidal residual currents and pulsating DC residual currents.

How is the ABB F204 A-25/0.03 installed?

The device is designed for standard DIN rail mounting inside electrical distribution boards, switchgear assemblies and control panels.

Trusted by Electrical Professionals Worldwide

ABB F200 Series residual current circuit breakers are widely trusted by electricians, panel builders and electrical engineers for dependable earth leakage protection, robust construction and reliable performance in demanding installations.
More Information
Manufacturer Part Number 2CSF204101R1250
Amperage 25A
Number of Poles 4 Pole
Trip Curve Type Type B 10KA
HS Code 85363030
Country of Manufacture Italy
Manufacturer ABB
Alternative Product SKU F204 A-25/0.03