We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
137X2960 Danfoss 200kW Three Phase iC7-Automation Variable Speed Drive
MPN: 137X2960
Alt. SKU: IC7-60FA3N05-385AE54F2+AGCX+AJFX+BAIP+BDBA+BEF1+BF20+DAAU
Why Choose the 137X2960?
The Danfoss 137X2960 (model code IC7-60FA3N05-385AE54F2+AGCX+AJFX+BAIP+BDBA+BEF1+BF20+DAAU) is a Variable speed drive (frequency converter) intended for panel installation where accurate motor control, repeatable commissioning, and reliable like-for-like replacement are required.
Configured with Power: 200 kW/300 hp, Current: 385 A, Supply: 380-500 V AC to support correct selection and like-for-like replacements.
Key Benefits
- Variable speed drive (frequency converter) for correct application matching
- Configured with Power: 200 kW/300 hp, Current: 385 A, Supply: 380-500 V AC.
- Suitable for panel installations where reliable commissioning is required.
- SKU and model code shown for procurement and like for like replacements.
Technical Specifications
- Product type: 3~
- Power rating: 200 kW/300 hp
- Mains voltage: 380-500 V AC
- Net weight: 87.61 Kilogram
- EAN: 5715253816227
- Additional drive features 1: None
- Additional drive features 2: None
- Additional drive features 3: None
- Additional drive features 4: None
- Additional drive features 5: None
- Ambient temp HO (1/10 min): 45°C/113°F
- Ambient temp HO2 (1/5 min): 45°C/113°F
- Ambient temp LO (1/10 min): 40°C/104°F
- Ambient temp. high overload: 45°C/113°F
- Ambient temp. normal overload: 40°C/104°F
- Cable entry and EMC plate: Standard plate
- Communication interface, X0: Ethernet port, no protocol
- Communication interface, X1/X2: EtherNet/IP OS7IP
- Continous current IH (1/10min): 302/302A
- Continous current IH (1/5min): 245/240A
- Continous current IL (1/10min): 385/364A
- Control panel: Control Panel 2.8 OPX20
- Current rating: 385 A
- Customer specific application: None
- Customer-specific label: None
- Customization file package ID: No customization
- DC terminals: None
- Efficiency class-Relative loss: IE2 - 1.84%
- EMC category: C2 category
- Enclosure rating: IP54 / TYPE 12
- Extra environmental protection: Coated boards
- Frame designation: FB09a
- Functional safety: STO, not upgradable
- Gross weight: 102.72 Kilogram
- Heat sink access panel: None
- Help Counter: 1
- High speed enabled: No
- Humidity protection device: None
- Input curent HO2 (1/5 min): 236/231A
- Input current HO (1/10 min): 291/291A
- Input current in High Overload: 291/291A
- Input current in Normal Overlo: 371/350A
- Input current LO (1/10 min): 371/350A
- Input frequency: 50/60Hz
- Input Voltage: 3x380-500V
- Integrated brake chopper: None
- Integrated common-mode filter: None
- Interface board: MicroSD card reader and RTC
- Language package: Global
- Main unit Depth: 378 MM / 14.9 IN
- Main unit Height: 999 MM / 39.3 IN
- Main unit Width: 327 MM / 12.9 IN
- Mains input device: AC fuses
- Maximum Power Loss LO [W]: 4053
- Modelcode01: IC7-60FA3N05-385AE54F2
- Modelcode02: +AGCX+AJFX
- Modelcode03: +BAIP+BDBA
- Modelcode04: +BEF1+BF20
- Modelcode05: +DAAU
- Option slot A: None
- Option slot B: None, not upgradable
- Option slot C: None
- Option slot D: None
- Option Slot E: None
- Output frequency: 0-590Hz
- Overload current IH (1/10min): 453/453A
- Overload current IH (1/5min): 368/360A
- Overload current IL (1/10min): 424/400A
- Product category: Frequency converter,air-cooled
- Product group: iC7-60
- Product series: iC7-Automation
- Product software ID: Latest released version
- Product specific marine cert.: None
- Protection rating: IP54/UL Type 12
- Short circuit current rating: 100kA
- Standard I/O: 4xDI, 2xDI/O, 2xAI, 1xAO, 2xRO
- Technical documentation: Installation guide
- Touch protection: None
- Typecode Part 1: 7FC-AUFA3N05-385AE54F2
- Typecode Part 2: -000153238
- Typical motor power PH (150%): 160KW(400V)/250HP(460V)
- Typical motor power PH2 (150%): 132KW(400V)/200HP(460V)
- Typical motor power PL (110%): 200KW(400V)/300HP(460V)
Frequently Asked Questions
What supply does Danfoss 137X2960 require?
What is the rated power for 137X2960?
Where is 137X2960 typically installed?
What does IP20 mean for 137X2960?
Can 137X2960 be used for pump and fan applications?
What should I check before ordering a like for like replacement for 137X2960?
| Manufacturer Part Number | 137X2960 |
|---|---|
| Barcode | 5715253816227 |
| Communication | EtherNet/IP OS7IP |
| Packed Quantity | 1 |
| Height | 999mm |
| Width | 327mm |
| Depth | 378mm |
| Ambient temp HO (1/10 min) | 45°C/113°F |
| Ambient temp HO2 (1/5 min) | 45°C/113°F |
| Ambient temp LO (1/10 min) | 40°C/104°F |
| Ambient temp. high overload | 45°C/113°F |
| Ambient temp. normal overload | 40°C/104°F |
| Amperage | 385A |
| A option | Option slot available for later addtion |
| B option | Option slot not available |
| C Option | Option slot available for later addtion |
| D Option | Option slot available for later addtion |
| E Option | Option slot available for later addtion |
| Cable entry and EMC plate | Standard plate |
| Continous current IH (1/10min) | 302/302A |
| Continous current IL (1/10min) | 385/364A |
| Brake - Safe-Stop | No brake chopper |
| Cable entry plate | Standard plate |
| Continous current IH (1/5min) | 245/240A |
| Coating PCB | Coated PCB |
| Control Panel | Control Panel 2.8 OPX20 |
| Control Panel Included | Yes |
| DC terminals | Yes |
| Efficiency class-Relative loss | IE2 - 1.84% |
| EMC Screen | Yes |
| Filter | C2 filter |
| Frame Size | FB09a |
| Functional safety | STO, not upgradable |
| HP Rating | 300 |
| Input curent HO2 (1/5 min) | 236/231A |
| Input current HO (1/10 min) | 291/291A |
| Input current in Normal Overload | 371/350A |
| Input current in High Overload (400/460VAC) | 291/291A |
| Input current LO (1/10 min) | 371/350A |
| Input Frequency | 50/60Hz |
| Input Voltage | 3x380-500VAC |
| Interface board | MicroSD card reader and RTC |
| Degree of protection (IP) | IP54 / TYPE 12 |
| KW Rating | 200kW |
| Mains input device | AC fuses |
| Maximum Power Loss LO [W] | 4053 |
| Onboard I/O | 4xDI,2xDI/O,2xAI,1xAO,2xRO |
| Output Frequency | 590Hz |
| Overload current IH (1/10min) | 453/453A |
| Overload current IH (1/5min) | 368/360A |
| Overload current IL (1/10min) | 424/400A |
| Output Phases | Three phase |
| Short Circuit Release | 100kA |
| VSD Range | Danfoss iC7-Automation |
| Typical motor power PH2 (150%) | 132KW(400V)/200HP(460V) |
| Manufacturer | Danfoss |
| Typical motor power PL (110%) | 200KW(400V)/300HP(460V) |
| Typical motor power PH (150%) | 160KW(400V)/250HP(460V) |
| Alternative Product SKU | IC7-60FA3N05-385AE54F2+AGCX+AJFX+BAIP+BDBA+BEF1+BF20+DAAU |