Do you need some help?

Call us now on: 01706 242050

137U5801 Danfoss 450kW iC7-Automation Inverter module

MPN: 137U5801

Alt. SKU: IC7-60SAIN05-820AE00F4+AEU1+AKFX+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK25+DAAU+EGIN+EHEN

Special Price £36,676.80 £30,564.00 Regular Price £45,846.00

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the 137U5801?

The Danfoss 137U5801 (model code IC7-60SAIN05-820AE00F4+AEU1+AKFX+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK25+DAAU+EGIN+EHEN) is a Drive option / expansion module intended for panel installation where accurate motor control, repeatable commissioning, and reliable like-for-like replacement are required.

Configured with Power: 450 kW/600 HP, Current: 820 A, Supply: 380-500 V AC to support correct selection and like-for-like replacements.

Key Benefits

  • Drive option / expansion module for correct application matching
  • Configured with Power: 450 kW/600 HP, Current: 820 A, Supply: 380-500 V AC.
  • Suitable for panel installations where reliable commissioning is required.
  • SKU and model code shown for procurement and like for like replacements.

Technical Specifications

  • Product type: Inverter module, INU
  • Power rating: 450 kW/600 HP
  • Mains voltage: 380-500 V AC
  • Net weight: 185 Kilogram
  • EAN: 5715253742588
  • AC voltage: 3X0-400/460/500VAC
  • Additional drive features 1: None
  • Additional drive features 2: None
  • Additional drive features 3: None
  • Additional drive features 4: None
  • Additional drive features 5: None
  • check if complete: OK
  • Communication interface, X0: Ethernet port, no protocol
  • Communication interface, X1/X2: Modbus TCP OS7MT
  • Continous current IH (1/5min): 681A(400VAC)/606A(460VAC)
  • Continous current IL (1/5min): 820A(400VAC)/730A(460VAC)
  • Control panel: Control Panel 2.8 OPX20
  • Control panel cable length: 1.5 m (5 ft)
  • Control panel mounting type: Flush mount
  • Control unit cable length: 2.5 m (8 ft), Fiber
  • Cooling circuit connector type: Not relevant
  • Cooling circuit hose length: Not relevant
  • Cooling type: Air Cooled
  • Current rating: 820 A
  • Customer specific application: None
  • Customer-specific label: None
  • Customization file package ID: No customization
  • DC Bus current: 913A(540VDC)
  • DC Bus voltage: 465-740VDC
  • DC fuses and devices: DC bus fuses
  • DC power: 493kW(540VDC)
  • Documentation language: English
  • EMC category: C4 category
  • Enclosure rating: IP00 / OPEN TYPE
  • Extra environmental protection: Coated boards
  • Frame designation: IR11
  • Functional safety: None, not upgradable
  • Gross weight: 215 Kilogram
  • Help Counter: 1
  • High speed enabled: No
  • Integration unit: Standard, with dU/dt filter
  • Language package: Global
  • Main unit Depth: 553MM/21.8IN
  • Main unit Height: 1302MM/51.3IN
  • Main unit Width: 235MM/9.3IN
  • Mains input device: None
  • Marine construction: None
  • Modelcode01: IC7-60SAIN05-820AE00F4
  • Modelcode02: +AEU1+AKFX
  • Modelcode03: +BAMT+BDC1+BEXX+BF20
  • Modelcode04: +BGK1+BH15+BK25
  • Modelcode06: +DAAU
  • Modelcode08: +EGIN+EHEN
  • Nominal AC current: 838A(400VAC)/746A(460VAC)
  • Option slot A: None, without mounting p
  • Option slot B: None, without mounting plate
  • Option slot C: None, without mounting plate
  • Option slot D: None, without mounting plate
  • Option slot E: None, without mounting plate
  • Option slot F: None, without mounting plate
  • Option slot G: None, without mounting plate
  • Option slot H: None, without mounting plate
  • Option slot I: None, without mounting plate
  • Option slot J: None, without mounting plate
  • Output frequency: 0-590Hz
  • Overload current IH (1/5min): 1022A(400VAC)/909A(460VAC)
  • Overload current IL (1/5min): 902A(400VAC)/803A(460VAC)
  • Product category: System module, air-cooled
  • Product Category -DrivesSymbol: System module, air-cooled
  • Product group: iC7-60
  • Product series: iC7-Automation
  • Product software ID: Latest released version
  • Product specific marine cert.: None
  • Product Type - DrivesSymbol: Inverter module
  • Protection rating: IP00/Open Type
  • Salescode part 1: IC7-60SAIN05-820AE00F4
  • Salescode part 2: +AEU1+AKFX
  • Salescode part 3: +BAMT+BDC1+BEXX+BF20
  • Salescode part 4: +BGK1+BH15+BK25
  • Salescode part 5: +DAAU
  • Salescode part 6: +EGIN+EHEN
  • Shipping package: Cardboard box package
  • Short circuit current rating: 100kA
  • Standard I/O: I/O and Relay Option OC7C1
  • StarCoupler board cable length: None
  • Start current Imax (3sec): 1158A
  • Storage temperature: -40...70°C/-40...158°F
  • Technical documentation: Installation guide
  • Typecode Part 1: 7SM-AUSAIN05-820AE00F4
  • Typecode Part 2: -000147387
  • Typical motor power PH2 (150%): 355kW(400VAC)/500Hp(460VAC)
  • Typical motor power PL (110%): 450kW(400VAC)/600Hp(460VAC)

Frequently Asked Questions

What supply does Danfoss 137U5801 require?
It is specified for 380-500 V AC. Match this to your incoming mains.
What is the rated power for 137U5801?
The listed power rating is 450 kW/600 HP. Confirm sizing against your motor and duty cycle.
Where is 137U5801 typically installed?
In control panels or cabinets. Follow Danfoss installation guidance for clearances, earthing, and protective devices.
What does IP20 mean for 137U5801?
IP20 indicates protection against finger contact and solid objects over 12.5 mm. Install in a suitable enclosure to meet your site requirements.
Can 137U5801 be used for pump and fan applications?
Yes, when correctly sized and commissioned, frequency converters are commonly used to control pumps and fans for smoother starts and improved process control.
What should I check before ordering a like for like replacement for 137U5801?
Confirm supply voltage, power rating, current rating, enclosure class, and required EMC filtering or communications options match the existing installation.
More Information
Manufacturer Part Number 137U5801
Barcode 5715253742588
Communication Modbus TCP OS7MT
Packed Quantity 1
Height 1302mm
Width 235mm
Depth 553mm
Amperage 820A
A option Option slot not available
B option Option slot not available
C Option None, without mounting plate
D Option None, without mounting plate
E Option None, without mounting plate
F Option None, without mounting plate
G Option None, without mounting plate
Brake - Safe-Stop No brake chopper
Continous current IH (1/5min) 681A(400VAC)/606A(460VAC)
Continous current IL (1/5min) 820A(400VAC)/730A(460VAC)
Coating PCB Coated PCB
Control Panel Control Panel 2.8 OPX20
Control Panel Included Yes
Control panel cable length 1.5 m (5 ft)
Control panel mounting type Flush mount
Control unit cable length 2.5 m (8 ft), Fiber
Cooling Air Cooling
DC Bus current 913A(540VDC)
DC Bus voltage 465-740VDC
DC fuses and devices DC bus fuses
DC power 493KW(540VDC)
Frame Size IR11
Functional safety None, not upgradable
HP Rating 600
Input Voltage 0-400/460/500VAC
Integration unit Standard, with dU/dt filter
Degree of protection (IP) IP00 / OPEN TYPE
KW Rating 450kW
Nominal AC current 838A(400VAC)/746A(460VAC)
Onboard I/O 6xDI,2xDO,2xAI,1xAO,thermister input,2xNO/NC,1xNO relays
Output Frequency 599Hz
Overload current IH (1/5min) 1022A(400VAC)/909A(460VAC)
Overload current IL (1/5min) 902A(400VAC)/803A(460VAC)
Short Circuit Release 100kA
StarCoupler board cable length 0.3 m (1 ft), Fiber
VSD Range Danfoss iC7-Automation
Typical motor power PH2 (150%) 355KW(400V)/500HP(460V)
Manufacturer Danfoss
Start current Imax (3sec) 1158A
Typical motor power PL (110%) 450KW(400V)/600HP(460V)
Alternative Product SKU IC7-60SAIN05-820AE00F4+AEU1+AKFX+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK25+DAAU+EGIN+EHEN
Write Your Own Review
You're reviewing:137U5801 Danfoss 450kW iC7-Automation Inverter module