We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
137N5423 Danfoss 355kW iC7-Automation Inverter module
MPN: 137N5423
Alt. SKU: IC7-60SAIN05-658AE00F4+AEC1+BAPR+BDC1+BEXX+BF20+BH50+BK50+CAC0+CBX0+DAAU+EGIN+EHEN
Why Choose the Danfoss iC7-Automation 137N5423?
The Danfoss 137N5423 is an iC7-Automation system module, air cooled inverter module (INU) built for high power industrial automation where cabinet integration, repeatable commissioning, and like for like replacement are essential. Supplied as an IP00 open type module for engineered control cabinets, it is designed for demanding industrial environments that require consistent configuration control and dependable performance.
This configuration is specified for three phase 380 to 500 V AC mains and is configured with PROFINET RT connectivity, Standard I/O with relay option, and a 2.8 inch OPX20 control panel to support commissioning, monitoring, and integration into standardised automation architectures.
Key Features
- System module, air cooled iC7-Automation inverter module (INU) for cabinet integrated drive systems.
- Phase and supply: three phase 380 to 500 V AC.
- Current rating: 658 A.
- Protection rating: IP00 open type for control cabinet installation.
- EMC category: C4 (industrial environment).
- Communications: PROFINET RT OS7PR.
- Standard I/O: I/O and Relay Option OC7C1.
- Control panel: 2.8 OPX20 for local commissioning and monitoring.
- Functional safety: None, not upgradable on this configuration.
Technical Specifications
- Manufacturer: Danfoss
- Product range: iC7-Automation
- Product category: System module, air cooled
- Product type: Inverter module, INU
- SKU: 137N5423
- Model code: IC7-60SAIN05-658AE00F4+AEC1+BAPR+BDC1+BEXX+BF20+BH50+BK50+CAC0+CBX0+DAAU+EGIN+EHEN
- Phase: Three phase
- Mains voltage: 380 to 500 V AC
- Current rating: 658 A
- Protection rating: IP00 open type
- EMC category: C4 category
- Frame: IR11
- Control panel: Control Panel 2.8 OPX20
- Standard I/O: I/O and Relay Option OC7C1
- Fieldbus: PROFINET RT OS7PR
- Functional safety: None, not upgradable
Applications
- Industrial automation systems requiring high current cabinet integrated system modules.
- Engineered drive cabinets using PROFINET RT networks and standardised I/O integration.
- OEM platforms where consistent module specification and straightforward service replacement are required.
Trusted By Customers Worldwide
"For high power cabinets, a defined iC7 system module configuration with PROFINET and consistent I/O makes build, commissioning, and service replacement far more predictable." Drives Engineer, UK
Frequently Asked Questions
What supply voltage does Danfoss 137N5423 require?
What is the current rating of 137N5423?
What does IP00 mean for this module?
Which communications are included?
Does 137N5423 include functional safety?
What is included for commissioning and monitoring?
| Manufacturer Part Number | 137N5423 |
|---|---|
| Barcode | 5715253633589 |
| Communication | PROFINET RT OS7PR |
| Packed Quantity | 1 |
| Height | 1302mm |
| Width | 235mm |
| Depth | 553mm |
| Amperage | 658A |
| A option | General Purpose I/O OC7C0 |
| B option | Option slot available for later addtion |
| C Option | None, without mounting plate |
| D Option | None, without mounting plate |
| E Option | None, without mounting plate |
| F Option | None, without mounting plate |
| G Option | None, without mounting plate |
| Brake - Safe-Stop | No brake chopper |
| Continous current IH (1/5min) | 547A(400VAC)/490A(460VAC) |
| Continous current IL (1/5min) | 658A(400VAC)/590A(460VAC) |
| Coating PCB | Coated PCB |
| Control Panel | Control Panel 2.8 OPX20 |
| Control Panel Included | Yes |
| Control panel cable length | 5.0 m (16 ft) |
| Control unit cable length | 5.0 m (16 ft), Fiber |
| Cooling | Air Cooling |
| DC Bus current | 721A(540VDC) |
| DC Bus voltage | 465-740VDC |
| DC fuses and devices | No DC input device |
| DC power | 389KW(540VDC) |
| Frame Size | IR11 |
| Functional safety | None, not upgradable |
| HP Rating | 500 |
| Input Voltage | 0-400/460/500VAC |
| Integration unit | Short, with CM filter |
| Degree of protection (IP) | IP00 / OPEN TYPE |
| KW Rating | 355kW |
| Nominal AC current | 672A(400VAC)/603A(460VAC) |
| Onboard I/O | 6xDI,2xDO,2xAI,1xAO,thermister input,2xNO/NC,1xNO relays |
| Output Frequency | 599Hz |
| Overload current IH (1/5min) | 821A(400VAC)/735A(460VAC) |
| Overload current IL (1/5min) | 724A(400VAC)/649A(460VAC) |
| Short Circuit Release | 100kA |
| StarCoupler board cable length | 0.3 m (1 ft), Fiber |
| VSD Range | Danfoss iC7-Automation |
| Typical motor power PH2 (150%) | 250KW(400V)/350HP(460V) |
| Manufacturer | Danfoss |
| Start current Imax (3sec) | 930A |
| Typical motor power PL (110%) | 355KW(400V)/500HP(460V) |
| Alternative Product SKU | IC7-60SAIN05-658AE00F4+AEC1+BAPR+BDC1+BEXX+BF20+BH50+BK50+CAC0+CBX0+DAAU+EGIN+EHEN |