Do you need some help?

Call us now on: 01706 242050

137N5213 Danfoss Three Phase iC7-Automation regenerative AFE

MPN: 137N5213

Alt. SKU: IC7-60SA3A05-580AE00F4+AE10+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+DAAU

Special Price £25,922.88 £21,602.40 Regular Price £32,403.60

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Danfoss iC7-Automation 137N5213?

The Danfoss 137N5213 is an iC7-Automation system module, air cooled configured for high power industrial automation systems where cabinet integration, repeatable commissioning, and like for like replacement are essential. This unit is a three phase regenerative AFE system module designed for robust grid and shaft performance in demanding industrial environments.

Based on the iC7 modular platform, this configuration is specified as an IP00 open type module for control cabinet installation, with Modbus TCP connectivity, a 2.8 inch OPX20 control panel for commissioning, and Standard I/O with relay option for integration into engineered drive systems.

Key Features

  • System module, air cooled iC7-Automation configuration for cabinet integration.
  • Regenerative AFE design for applications requiring grid side performance.
  • Mains voltage: three phase 380 to 500 V AC.
  • Current rating: 580 A.
  • Protection rating: IP00 open type.
  • EMC category: C4 (industrial environment).
  • Communications: Modbus TCP OS7MT.
  • Control panel: 2.8 OPX20.
  • Standard I/O: I/O and Relay Option OC7C1.
  • Functional safety: None, not upgradable on this configuration.

Technical Specifications

  • Manufacturer: Danfoss
  • Product range: iC7-Automation
  • Product category: System module, air cooled
  • System type: Regenerative, AFE
  • Phase: Three phase
  • SKU: 137N5213
  • Model code: IC7-60SA3A05-580AE00F4+AE10+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+DAAU
  • Mains voltage: 380 to 500 V AC
  • Current rating: 580 A
  • Protection rating: IP00 open type
  • EMC category: C4 category
  • Frame: AR11
  • Control panel: 2.8 OPX20
  • Standard I/O: I/O and Relay Option OC7C1
  • Communication: Modbus TCP OS7MT
  • Functional safety: None, not upgradable

Applications

  • High power industrial automation systems using cabinet integrated system modules.
  • Regenerative drive systems where AFE architecture is required for the installation design.
  • Standardised OEM platforms requiring consistent configuration and service replacement by SKU.

Trusted By Customers Worldwide

"For engineered cabinets, having a defined iC7 system module configuration with AFE and standard I/O keeps builds consistent and service replacement straightforward." Drives Engineer, UK

Frequently Asked Questions

What supply voltage does Danfoss 137N5213 require?
It is specified for three phase 380 to 500 V AC mains.
What is the rated current of 137N5213?
The configuration is listed with a 580 A current rating.
What does IP00 mean for this system module?
IP00 open type indicates it must be installed inside a suitable control cabinet with appropriate protection, ventilation, and clearances.
Which communications are included?
This configuration is listed with Modbus TCP OS7MT.
Does this configuration include functional safety?
No. It is listed as none, not upgradable for functional safety on this model code.
What is meant by regenerative AFE on this module?
It is described as a regenerative, active front end (AFE) system module configuration intended for engineered drive systems that require grid side performance as part of the cabinet design.
More Information
Manufacturer Part Number 137N5213
Barcode 5715253631127
Communication Modbus TCP OS7MT
Packed Quantity 1
Height 1530mm
Width 235mm
Depth 553mm
Apparent power 411KVA(400VAC)/442KVA(480VAC)
Amperage 580A
A option Option slot not available
B option Option slot not available
C Option None, without mounting plate
D Option None, without mounting plate
E Option None, without mounting plate
F Option None, without mounting plate
G Option None, without mounting plate
Brake - Safe-Stop No brake chopper
Coating PCB Coated PCB
Control Panel Control Panel 2.8 OPX20
Control Panel Included Yes
Control panel cable length 1.5 m (5 ft)
Control panel mounting type Flush mount
Control unit cable length 1.5 m (5 ft), Fiber
Cooling Air Cooling
DC Bus current 677A(594VDC)
DC Bus voltage 465-740VDC
DC fuses and devices No DC input device
DC power 402KW(594VDC)
Frame Size AR11
Functional safety None, not upgradable
Input Frequency 50/60Hz
Input Voltage 3x380-500VAC
Integration unit Standard, no filter
Degree of protection (IP) IP00 / OPEN TYPE
Nominal AC current 593A(400VAC)/531A(480VAC)
Onboard I/O 6xDI,2xDO,2xAI,1xAO,thermister input,2xNO/NC,1xNO relays
Output Phases Three phase
Short Circuit Release 100kA
StarCoupler board cable length 0.3 m (1 ft), Fiber
VSD Range Danfoss iC7-Automation
Manufacturer Danfoss
Alternative Product SKU IC7-60SA3A05-580AE00F4+AE10+BAMT+BDC1+BEXX+BF20+BGK1+BH15+BK15+DAAU
Write Your Own Review