We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
134U5198 Danfoss VLT HVAC Drive 18.5KW/25HP 380-480VAC IP55
MPN: 134U5198
Alt. SKU: FC-102P18KT4E55H3TGXXXXSXXXXANBXCXXXXDX
Why Choose the Danfoss 134U5198 VLT® HVAC Drive?
The Danfoss 134U5198 is a powerful and reliable variable frequency drive (VFD) from the Danfoss VLT® HVAC Drive FC 102 series, engineered specifically for heating, ventilation, air conditioning and refrigeration systems. Designed for demanding building services applications, it delivers precise motor speed control while helping reduce energy consumption and operating costs.
As part of the VLT® HVAC Drive range, the 134U5198 incorporates advanced HVAC functionality for pumps, fans and compressors. Its integrated Safe Stop function, graphical local control panel and EtherNet/IP communication capability simplify commissioning and integration with modern building management and industrial automation systems.
With a rated output power of 18.5 kW (25 HP) and a three-phase 380–480 V AC supply, the Danfoss 134U5198 is ideally suited to larger HVAC installations. The robust IP55 / Type 12 enclosure provides excellent protection against dust and water ingress, making it suitable for wall-mounted installations in plant rooms and industrial environments.
Key Advantages
- Dedicated HVAC variable frequency drive for fans, pumps and compressors.
- 18.5 kW (25 HP) power rating for demanding HVAC applications.
- Three-phase 380–480 V AC input for industrial and commercial installations.
- IP55 / Type 12 enclosure suitable for challenging environments.
- Safe Stop functionality supports enhanced operational safety.
- EtherNet/IP MCA 121 option enables seamless automation integration.
- Integrated RFI Class A1/B (C1) EMC filter helps reduce interference.
Key Features
- Danfoss VLT® HVAC Drive FC 102 series.
- 18.5 kW rated output power.
- 25 HP motor power rating.
- Three-phase 380–480 V AC input supply.
- IP55 / Type 12 protection rating.
- RFI Class A1/B (C1) EMC filter.
- Integrated Safe Stop function.
- Graphical local control panel.
- EtherNet/IP MCA 121 communication option.
- Not coated PCB.
- No mains option fitted.
- Frame size B1.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC 102
- Model: 134U5198
- Type code: FC-102P18KT4E55H3TGXXXXSXXXXANBXCXXXXDX
- Product type: Variable frequency drive
- Rated output power: 18.5 kW
- Horsepower rating: 25 HP
- Input voltage: 380–480 V AC
- Input phases: Three-phase
- Application: HVAC motor control
- Protection rating: IP55 / Type 12
- RFI filter: Class A1/B (C1)
- Brake / safety function: Safe Stop
- A option: EtherNet/IP MCA 121
- B option: No B option
- Local control panel: Graphical LCP
- PCB coating: Not coated PCB
- Mains option: No mains option
- Frame size: B1
- Dimensions (H × W × D): approx. 480 × 242 × 260 mm
- Barcode: 5710108012281
Advanced HVAC Motor Control
The Danfoss FC 102 range is specifically developed for HVAC applications, providing intelligent control of pumps, fans and compressors. By adjusting motor speed to match system demand, the drive helps reduce energy usage while improving comfort, process control and equipment lifespan.
Integrated HVAC-specific functions, flexible communication options and rugged enclosure designs make the FC 102 series a preferred solution for building automation systems, commercial facilities and industrial HVAC installations.
Typical Applications
- Air handling units and ventilation systems.
- Commercial HVAC plant rooms.
- Industrial fans and blowers.
- Heating and chilled water circulation pumps.
- Cooling towers and condenser systems.
- Refrigeration and compressor control systems.
- Building management and automation systems using EtherNet/IP.
Frequently Asked Questions
What is the Danfoss 134U5198 used for?
The Danfoss 134U5198 controls the speed of three-phase AC motors used in HVAC applications including pumps, fans, compressors and ventilation systems.
What motor power is supported by this drive?
This drive is rated for motors up to 18.5 kW (25 HP).
What supply voltage does the drive require?
The 134U5198 operates from a three-phase 380–480 V AC supply.
What enclosure rating does this drive have?
The drive features an IP55 / Type 12 enclosure suitable for demanding HVAC and industrial environments.
Does the Danfoss 134U5198 support industrial networking?
Yes, this model includes an EtherNet/IP MCA 121 communication option for integration with automation and building management systems.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC drives are widely used by building services engineers and facilities managers to deliver reliable motor control, energy efficiency and long-term performance in modern HVAC installations.
| Manufacturer Part Number | 134U5198 |
|---|---|
| Barcode | 5710108012281 |
| Height | 480mm |
| Width | 242mm |
| Depth | 260mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 18.5kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P18KT4E55H3TGXXXXSXXXXANBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.