We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
134U0572 Danfoss VLT HVAC Drive 11KW/15HP 380-480VAC IP66
MPN: 134U0572
Alt. SKU: FC-102P11KT4E66H2TGXXXXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 134U0572 VLT HVAC Drive?
The Danfoss 134U0572 is a robust VLT® HVAC Drive FC-102 variable frequency drive (VFD) designed for precise and energy-efficient motor speed control in heating, ventilation and air conditioning systems. Built for demanding HVAC environments, this drive helps optimise fan, pump and compressor performance while reducing energy consumption and mechanical stress.
As part of the proven Danfoss VLT® HVAC Drive FC-102 series, the 134U0572 provides dedicated HVAC functionality, dependable motor control and straightforward commissioning. Its advanced drive platform is suitable for commercial buildings, industrial plant rooms and building services applications requiring stable and repeatable operation.
With a rated output power of 11 kW / 15 HP and a three-phase 380–480 V AC supply, the Danfoss 134U0572 is ideal for HVAC motors used in ventilation, pumping and air handling systems. The IP66 / NEMA 4X B1 frame enclosure provides high environmental protection for installations where resistance to dust, water and harsh conditions is required.
Key Advantages
- Dedicated variable frequency drive for HVAC applications.
- 11 kW / 15 HP motor power rating for fan, pump and compressor systems.
- Three-phase 380–480 V AC input for commercial and industrial power supplies.
- IP66 / NEMA 4X enclosure for demanding installation environments.
- RFI Class A2 (C3) filtering for EMC performance.
- Integrated Safe Stop functionality for enhanced operational safety.
- Graphical local control panel for simple setup, monitoring and commissioning.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 11 kW / 15 HP rated output power.
- Three-phase 380–480 V AC input supply.
- IP66 / NEMA 4X B1 frame enclosure.
- RFI Class A2 (C3) EMC filtering.
- Integrated Safe Stop function.
- No A option and no B option fitted.
- Graphical local control panel included.
- Not coated PCB configuration.
- No mains option fitted.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: 134U0572
- Model code: FC-102P11KT4E66H2TGXXXXSXXXXAXBXCXXXXDX
- Product type: AC variable frequency drive
- Rated output power: 11 kW / 15 HP
- Input voltage: 380–480 V AC
- Input phases: Three phase
- Frequency: 50 / 60 Hz
- Protection rating: IP66 / NEMA 4X
- Frame size: B1
- EMC / RFI filter: RFI Class A2 (C3)
- Safety function: Safe Stop
- A option: No A option
- B option: No B option
- Control panel: Graphical local control panel
- PCB coating: Not coated PCB
- Mains option: No mains option
- Dimensions (H × W × D): approx. 480 × 242 × 260 mm
- Barcode: 5710107965731
Efficient Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss VLT® HVAC Drive FC-102 regulate motor speed by adjusting output frequency and voltage. This enables HVAC equipment to operate according to actual demand, improving energy efficiency while reducing wear on motors, fans, pumps and connected mechanical components.
The FC-102 range is developed for HVAC engineers, building services contractors and facilities teams requiring stable and dependable motor control. Its HVAC-focused design supports comfortable building operation, reduced running costs and long-term reliability in demanding commercial and industrial environments.
Typical Applications
- HVAC fan speed control.
- Air handling units and ventilation systems.
- Heating and cooling circulation pumps.
- Chilled water and condenser water pumps.
- Cooling towers and refrigeration systems.
- Commercial building services.
- Industrial HVAC installations.
- Building management and automation systems.
Frequently Asked Questions
What is the Danfoss 134U0572 used for?
The Danfoss 134U0572 is used to control AC motor speed in HVAC applications such as fans, pumps, air handling units, ventilation systems and refrigeration equipment.
What motor power does this drive support?
This model is rated for approximately 11 kW / 15 HP motors.
What supply voltage does the Danfoss 134U0572 require?
The drive operates from a three-phase 380–480 V AC supply.
What enclosure rating does this drive have?
The Danfoss 134U0572 has an IP66 / NEMA 4X enclosure rating in a B1 frame.
Does the Danfoss 134U0572 include Safe Stop?
Yes, this configuration includes integrated Safe Stop functionality for enhanced operational safety.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC Drives are widely used by building services engineers, system integrators and facilities teams to deliver efficient, reliable and precise motor control for HVAC equipment in commercial and industrial installations.
| Manufacturer Part Number | 134U0572 |
|---|---|
| Barcode | 5710107965731 |
| Height | 480mm |
| Width | 242mm |
| Depth | 260mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP66 |
| KW Rating | 11kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P11KT4E66H2TGXXXXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.