We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
134L4808 Danfoss VLT HVAC Drive 2.2KW/3.0HP 380-480VAC IP20
MPN: 134L4808
Alt. SKU: FC-102P2K2T4E20H1TGXXXXSXXXXAXBPCXXXXD0
Why Choose the Danfoss 134L4808 VLT HVAC Drive?
The Danfoss 134L4808 is a high-performance AC variable frequency drive (VFD) from the renowned Danfoss VLT® HVAC Drive FC 102 series, engineered specifically for heating, ventilation and air conditioning applications. Designed to deliver precise motor speed control and significant energy savings, this drive provides reliable performance for pumps, fans, compressors and other HVAC equipment.
Built with advanced motor control technology, the VLT HVAC Drive FC 102 helps optimise system efficiency while reducing energy consumption and operational costs. Integrated safety functions, intelligent control capabilities and robust construction make it an excellent choice for commercial buildings, industrial facilities and critical HVAC infrastructure.
With a rated output power of 2.2 kW and a three-phase 380-480 V AC supply, the 134L4808 offers dependable performance in demanding HVAC environments. Its compact IP20 chassis design allows easy installation within electrical control panels and switchgear assemblies.
Key Advantages
- Purpose-built HVAC variable frequency drive for energy-efficient motor control.
- 2.2 kW output power suitable for pumps, fans and compressors.
- Three-phase 380-480 V AC input for commercial and industrial installations.
- Integrated Safe Torque Off (STO) safety functionality.
- Built-in intelligence for optimised HVAC process control.
- Compact design simplifies panel installation and commissioning.
- Helps reduce energy consumption and operating costs.
Key Features
- Danfoss VLT® HVAC Drive FC 102 series.
- 2.2 kW rated output power.
- 4.8 A continuous output current.
- 380-480 V AC three-phase input supply.
- IP20 chassis enclosure.
- RFI Class A1/B (C1) integrated filter.
- Safe Torque Off (STO) functionality.
- Graphical Local Control Panel (LCP).
- MCB-105 relay card installed.
- 24 V DC backup capability via MCB-107 option.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC 102
- Part Number: 134L4808
- Model Code: FC-102P2K2T4E20H1TGXXXXSXXXXAXBPCXXXXD0
- Product type: AC variable frequency drive
- Rated output power: 2.2 kW (3 HP)
- Continuous output current: 4.8 A
- Input voltage: 380-480 V AC
- Input phases: Three-phase
- Protection rating: IP20
- RFI filter: Class A1/B (C1)
- Safety function: Safe Torque Off (STO)
- Frame size: A2
- Dimensions (H × W × D): 268 × 90 × 205 mm
- Weight: 4.71 kg
- EAN: 5710107799862
Optimised HVAC Motor Control
The Danfoss FC 102 HVAC Drive is designed specifically to improve the performance of heating, ventilation and air conditioning systems. By precisely regulating motor speed, the drive reduces energy consumption, minimises mechanical wear and improves overall system reliability.
Integrated HVAC-specific functionality enables smooth operation of pumps, fans and compressors while helping facilities comply with modern energy-efficiency requirements. Advanced protection and safety features ensure dependable operation in critical building services applications.
Typical Applications
- HVAC fan control systems.
- Building ventilation equipment.
- Chilled water and heating pumps.
- Air handling units (AHUs).
- Commercial and industrial refrigeration systems.
- Energy management and building automation systems.
Frequently Asked Questions
What is the Danfoss 134L4808 used for?
The drive is designed for HVAC applications including pumps, fans, compressors and ventilation systems requiring efficient variable speed motor control.
What motor power does the 134L4808 support?
The drive is rated for 2.2 kW (3 HP) motor applications.
What supply voltage is required?
The drive operates from a three-phase 380-480 V AC power supply.
Does the drive include safety features?
Yes, it includes integrated Safe Torque Off (STO) functionality to support safe machine operation.
Where is the drive typically installed?
The IP20 chassis version is designed for installation within electrical control panels or suitable enclosures.
Trusted for HVAC Performance Worldwide
Danfoss VLT® HVAC Drive FC 102 units are widely used by building services engineers, facility managers and automation specialists to improve energy efficiency, enhance process control and reduce operating costs in HVAC systems.
| Manufacturer Part Number | 134L4808 |
|---|---|
| Barcode | 5710107799862 |
| Height | 268mm |
| Width | 90mm |
| Depth | 205mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP20 |
| KW Rating | 2.2kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P2K2T4E20H1TGXXXXSXXXXAXBPCXXXXD0 |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.