We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
131U9352 Danfoss VLT FC-102 HVAC Drive 1.1 KW / 1.5 HP, 380 - 480 VAC, IP55
MPN: 131U9352
Alt. SKU: FC-102P1K1T4Z55H3XNXXOXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 131U9352 VLT HVAC Drive FC-102?
The Danfoss 131U9352 is a compact and efficient VLT® HVAC Drive FC-102 frequency converter designed for reliable motor speed control in heating, ventilation, air conditioning and refrigeration systems. Built specifically for HVAC applications, this drive provides accurate control of fans, pumps and compressors while helping improve energy performance and operational reliability.
As part of the trusted Danfoss VLT HVAC Drive FC-102 series, this unit combines dedicated HVAC functionality with durable construction and practical configuration options. It is suitable for commercial buildings, plant rooms, air handling systems and industrial HVAC installations where reliable motor control, straightforward commissioning and dependable operation are essential.
With a rated output power of 1.1 kW / 1.5 HP, a three-phase 380-480 V AC supply and an IP55 / Type 12 enclosure, the Danfoss 131U9352 is well suited to protected HVAC installations requiring dependable speed control. Its full model code is FC-102P1K1T4Z55H3XNXXOXSXXXXAXBXCXXXXDX.
Key Advantages
- Dedicated HVAC variable speed drive for fans, pumps and compressors.
- 1.1 kW / 1.5 HP rated output power for smaller HVAC motor control applications.
- Three-phase 380-480 V AC input compatible with industrial and commercial power systems.
- IP55 / Type 12 enclosure for enhanced environmental protection.
- RFI Class A1/B (C1) filter for improved electromagnetic compatibility.
- Numerical local control panel for practical setup, monitoring and operation.
- Metric thread cable entry configuration for straightforward installation.
- Designed to support energy-efficient operation, smoother motor control and reduced running costs.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 1.1 kW / 1.5 HP rated output power.
- 3 A continuous current rating.
- Three-phase 380-480 V AC mains voltage.
- IP55 / Type 12 enclosure protection.
- RFI Class A1/B (C1) filter.
- No brake chopper configuration.
- Numerical local control panel.
- Not coated PCB.
- No mains option.
- Metric thread cable entries.
- Frame size A4.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- SKU: 131U9352
- Model code: FC-102P1K1T4Z55H3XNXXOXSXXXXAXBXCXXXXDX
- Product type: Frequency converter / HVAC variable speed drive
- Rated output power: 1.1 kW / 1.5 HP
- Continuous current: 3 A
- Intermittent current: 3.3 A
- Mains voltage: 380-480 V AC
- Input phases: Three phase
- kVA rating: 2.08 kVA
- Power loss: approx. 58 W
- Enclosure rating: IP55 / Type 12
- RFI filter: H3 RFI Class A1/B (C1)
- Brake chopper: No brake chopper
- Local control panel: Numerical local control panel
- PCB coating: Not coated PCB
- Mains option: No mains option
- Adaptation A: Metric thread cable entry
- Adaptation B: No adaptation
- A option: No A option
- B option: No B option
- C0 option: No C0 option
- C1 option: No C1 option
- D option: No D option
- Software release: Latest release standard software
- Frame size: A4
- Dimensions (H × W × D): approx. 391 × 200 × 177 mm
- Depth with Option A/B: approx. 177 mm
- Net weight: approx. 7.57 kg
- Gross weight: approx. 8.306 kg
- Volume: approx. 47.293 L
- EAN: 5710107009206
Efficient Motor Control for HVAC Systems
The Danfoss VLT HVAC Drive FC-102 regulates motor speed by adjusting output frequency and voltage. This allows HVAC equipment to respond accurately to system demand, helping maintain consistent airflow, pressure and temperature while reducing unnecessary energy consumption.
By matching motor output to the actual operating requirement, the 131U9352 helps reduce mechanical stress on connected equipment. This supports smoother starts, quieter operation, improved equipment life and dependable performance in commercial and industrial HVAC installations.
Typical Applications
- Heating, ventilation and air conditioning systems.
- Commercial building ventilation plant.
- Fan and pump speed control.
- Air handling units and extraction systems.
- Refrigeration and cooling systems.
- Compressor control applications.
- Plant room and building services automation.
- Industrial HVAC installations requiring protected IP55 drive mounting.
Frequently Asked Questions
What is the Danfoss 131U9352 used for?
The Danfoss 131U9352 is used to control motor speed in HVAC applications such as fans, pumps, compressors, ventilation equipment and refrigeration systems.
What power rating does this drive have?
This VLT HVAC Drive FC-102 has a rated output power of 1.1 kW / 1.5 HP.
What supply voltage does the Danfoss 131U9352 require?
The drive operates from a three-phase 380-480 V AC supply.
What enclosure rating does this drive have?
The Danfoss 131U9352 has an IP55 / Type 12 enclosure, providing enhanced protection for suitable HVAC and building services environments.
Does this version include a local control panel?
Yes. This configuration includes a numerical local control panel for practical setup, monitoring and operation.
Trusted by HVAC Engineers Worldwide
Danfoss VLT HVAC Drive FC-102 frequency converters are widely used by HVAC engineers, facilities managers and automation specialists to deliver reliable motor control, efficient performance and dependable operation in building services applications.
| Manufacturer Part Number | 131U9352 |
|---|---|
| Barcode | 5710107009206 |
| Height | 391mm |
| Width | 200mm |
| Depth | 177mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 1.1kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P1K1T4Z55H3XNXXOXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.