Why Choose the Danfoss 131U8430 VLT® HVAC Drive FC-102?
The Danfoss 131U8430 is a powerful and reliable HVAC variable frequency drive (VFD) designed for precise motor speed control in heating, ventilation, air conditioning and refrigeration systems. As part of the established Danfoss VLT® HVAC Drive FC-102 series, it is engineered to optimise energy efficiency, improve system control and support dependable HVAC automation.
This drive provides advanced motor control functionality for commercial buildings, industrial facilities and large plant room environments. The FC-102 series includes dedicated HVAC features that simplify commissioning, support energy savings and allow efficient control of fans, pumps and compressors.
With a rated output power of 37 kW / 50 HP and a three-phase 380-480 V AC supply, the Danfoss 131U8430 is ideal for larger HVAC motor applications. Its IP55 / Type 12 enclosure, graphical local control panel and MCB-109 I/O with RTC back-up provide a robust and practical solution for demanding installations.
Key Advantages
- Dedicated HVAC variable speed drive for fans, pumps and compressors.
- 37 kW / 50 HP motor power rating suitable for larger HVAC systems.
- Three-phase 380-480 V AC input compatible with industrial power networks.
- IP55 / Type 12 enclosure for improved environmental protection.
- Integrated RFI Class A1/B (C1) filter for electromagnetic compatibility.
- Graphical local control panel for simplified setup and monitoring.
- MCB-109 I/O with RTC back-up for enhanced control and system functionality.
- Designed to reduce energy use, improve system control and lower running costs.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 37 kW / 50 HP rated output power.
- 73 A continuous current rating.
- Three-phase 380-480 V AC mains supply.
- IP55 / Type 12 enclosure protection.
- Integrated RFI Class A1/B (C1) filter.
- Graphical local control panel included.
- No brake chopper configuration.
- Not coated PCB.
- No mains option.
- Standard cable entries.
- MCB-109 I/O, RTC back-up B option.
- Frame size C1.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: 131U8430
- Model code: FC-102P37KT4E55H3XGXXXXSXXXXAXB0CXXXXDX
- Product type: HVAC variable frequency drive
- Rated output power: 37 kW / 50 HP
- Continuous current rating: 73 A
- Input voltage: 380-480 V AC
- Input phases: 3-phase
- Frequency: 50 / 60 Hz
- Protection rating: IP55 / Type 12
- RFI filter: Class A1/B (C1)
- Brake chopper: No
- Local control panel: Graphical LCP
- PCB coating: Not coated
- Mains option: No mains option
- Cable entries: Standard
- B option: MCB-109 I/O, RTC back-up
- Frame size: C1
Efficient Motor Control for HVAC Systems
The Danfoss FC-102 HVAC Drive controls motor speed by adjusting output frequency and voltage according to system demand. This allows HVAC equipment to run more efficiently while maintaining accurate airflow, pressure and temperature control throughout the installation.
Purpose-built for HVAC environments, the FC-102 range supports dependable operation in fan, pump and compressor applications. Its dedicated control functions, robust enclosure and user-friendly interface make it a trusted solution for building services engineers, facilities managers and automation specialists.
Typical Applications
- Large commercial HVAC systems.
- Air handling units and ventilation systems.
- Supply and extract fans.
- Heating and chilled water pumps.
- Refrigeration and cooling systems.
- Industrial plant rooms and building automation systems.
Frequently Asked Questions
What is the Danfoss 131U8430 used for?
The Danfoss 131U8430 is used to control motor speed in HVAC applications including fans, pumps, compressors and ventilation systems.
What motor power does this drive support?
This drive provides a rated output power of approximately 37 kW / 50 HP.
What supply voltage does the drive require?
The Danfoss 131U8430 operates from a three-phase 380-480 V AC supply.
Does this drive include a local control panel?
Yes, this configuration includes a graphical local control panel for commissioning, monitoring and operation.
What protection rating does this drive have?
The drive features an IP55 / Type 12 enclosure, making it suitable for demanding HVAC and plant room environments.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC Drive FC-102 frequency converters are widely used by HVAC engineers, facilities managers and automation specialists to deliver reliable motor control, improved energy efficiency and dependable long-term performance.
| Manufacturer Part Number | 131U8430 |
|---|---|
| Barcode | 5702427999305 |
| Height | 680mm |
| Width | 308mm |
| Depth | 310mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 37kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P37KT4E55H3XGXXXXSXXXXAXB0CXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.