We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
131U5081 Danfoss VLT FC-102 HVAC Drive 3.0 KW / 4.0 HP, 380 - 480 VAC, IP55
MPN: 131U5081
Alt. SKU: FC-102P3K0T4Z55H1XGX1OXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 131U5081 VLT® HVAC Drive FC-102?
The Danfoss 131U5081 is a compact and reliable variable frequency drive (VFD) designed for precise speed control of three-phase motors in heating, ventilation, air conditioning and refrigeration systems. As part of the trusted Danfoss VLT® HVAC Drive FC-102 series, it is engineered to improve energy efficiency, optimise motor performance and support dependable operation in commercial and industrial HVAC applications.
This drive helps HVAC equipment operate according to real system demand by adjusting motor speed instead of relying on fixed-speed operation. The FC-102 platform provides dedicated HVAC functionality, robust construction and flexible integration with building automation systems, making it suitable for new installations, upgrades and replacement drive applications.
With a rated output power of 3.0 kW / 4.0 HP and a three-phase 380–480 V AC supply, the Danfoss 131U5081 is ideal for fans, pumps, compressors and ventilation equipment. Its IP55 / Type 12 enclosure, RFI Class A1/B (C1) filter, graphical local control panel and mains disconnect support reliable installation, commissioning and operation in demanding HVAC environments.
Key Advantages
- Dedicated HVAC variable frequency drive for fans, pumps and compressors.
- 3.0 kW / 4.0 HP motor power rating for commercial HVAC motor control applications.
- Three-phase 380–480 V AC input compatible with industrial and commercial power systems.
- IP55 / Type 12 enclosure for enhanced environmental protection.
- Integrated RFI Class A1/B (C1) filter for improved electromagnetic compatibility.
- Graphical local control panel and mains disconnect for practical setup and maintenance.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 3.0 kW / 4.0 HP rated output power.
- 7.2 A continuous current rating.
- Three-phase 380–480 V AC mains voltage.
- IP55 / Type 12 enclosure protection.
- Integrated H1 RFI Class A1/B (C1) filter.
- No brake chopper configuration.
- Graphical local control panel included.
- Not coated PCB.
- Mains disconnect fitted.
- Metric thread cable entry adaptation.
- Frame size A4.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: FC-102P3K0T4Z55H1XGX1OXSXXXXAXBXCXXXXDX
- SKU: 131U5081
- Product type: Frequency converter / HVAC variable speed drive
- Rated output power: 3.0 kW / 4.0 HP
- Continuous current: 7.2 A
- Intermittent current: 7.92 A
- Input voltage: 380–480 V AC
- Input phases: Three phase
- Apparent power: 4.99 kVA
- Protection rating: IP55 / Type 12
- RFI filter: H1 RFI Class A1/B (C1)
- Brake chopper: No brake chopper
- Control panel: Graphical local control panel
- PCB coating: Not coated PCB
- Mains option: Mains disconnect
- Cable entry: Metric thread cable entry
- Frame size: A4
- Software: Latest standard software release
Reliable Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss VLT® HVAC Drive FC-102 regulate motor speed by adjusting output voltage and frequency. This allows HVAC equipment to match output to system demand, helping reduce energy use, mechanical stress and unnecessary wear.
The FC-102 series is purpose-built for heating, ventilation, air conditioning and refrigeration applications. Its dedicated HVAC functions support stable control of fans, pumps and compressors while helping improve system reliability and reduce operating costs.
Typical Applications
- Ventilation and extraction systems.
- Air handling units.
- Heating and cooling circulation pumps.
- Compressors and refrigeration systems.
- Commercial HVAC installations.
- Building management and automation systems.
Frequently Asked Questions
What is the Danfoss 131U5081 used for?
The Danfoss 131U5081 is used to control three-phase motors in HVAC applications such as fans, pumps, compressors, ventilation systems and refrigeration plant.
What motor power is supported by this drive?
The drive supports motors with a rated output power of approximately 3.0 kW / 4.0 HP.
What supply voltage does the drive require?
The Danfoss 131U5081 operates from a three-phase 380–480 V AC supply.
What enclosure rating does this drive have?
This drive has an IP55 / Type 12 enclosure, making it suitable for demanding HVAC and building services environments.
Does the Danfoss 131U5081 include a local control panel?
Yes, this configuration includes a graphical local control panel for straightforward commissioning, monitoring and operation.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC Drive FC-102 frequency converters are widely used by HVAC engineers, contractors and building services professionals to deliver efficient motor control, reliable operation and reduced energy consumption in modern buildings.
| Manufacturer Part Number | 131U5081 |
|---|---|
| Barcode | 5702427964440 |
| Height | 391mm |
| Width | 200mm |
| Depth | 177mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 3kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P3K0T4Z55H1XGX1OXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.