We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
131U2928 Danfoss VLT FC-102 HVAC Drive 1.5 KW / 2.0 HP, 380 - 480 VAC, IP55
MPN: 131U2928
Alt. SKU: FC-102P1K5T4Z55H2XXXXOXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 131U2928 VLT® HVAC Drive FC-102?
The Danfoss 131U2928 is a compact and efficient variable frequency drive (VFD) designed for accurate speed control of three-phase motors in heating, ventilation, air conditioning and refrigeration systems. As part of the proven Danfoss VLT® HVAC Drive FC-102 series, it is engineered to improve HVAC performance, reduce energy consumption and provide dependable motor control in commercial building services applications.
This drive provides dedicated HVAC functionality, reliable motor regulation and straightforward integration into building management and automation systems. The FC-102 platform is widely used for fans, pumps and compressors where precise control, energy efficiency and long-term operational reliability are essential.
With a rated output power of 1.5 kW / 2.0 HP and a three-phase 380–480 V AC supply, the Danfoss 131U2928 is ideal for smaller HVAC motor applications. Its IP55 / Type 12 A4 frame enclosure, integrated RFI Class A2 (C3) filter and metric cable entry configuration make it a practical choice for demanding building services environments.
Key Advantages
- Dedicated HVAC variable frequency drive for fans, pumps and refrigeration equipment.
- 1.5 kW / 2.0 HP power rating suitable for smaller commercial HVAC motor control.
- Three-phase 380–480 V AC input compatible with industrial and commercial power systems.
- IP55 / Type 12 enclosure for dependable installation in demanding environments.
- Integrated RFI Class A2 (C3) filter for EMC performance.
- Metric thread cable entry adaptation for practical installation.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 1.5 kW / 2.0 HP rated output power.
- Three-phase 380–480 V AC input supply.
- IP55 / Type 12 A4 frame enclosure.
- Integrated RFI Class A2 (C3) filter.
- No brake chopper configuration.
- No local control panel fitted.
- Not coated PCB configuration.
- No mains option fitted.
- No A option and no B option.
- No C1 option and no D option.
- Metric thread cable entry adaptation.
- Latest standard software release.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: FC-102P1K5T4Z55H2XXXXOXSXXXXAXBXCXXXXDX
- SKU: 131U2928
- Product type: Frequency converter / variable speed drive
- Rated output power: 1.5 kW / 2.0 HP
- Input voltage: 380–480 V AC
- Input phases: Three phase
- Protection rating: IP55 / Type 12
- Frame size: A4
- RFI filter: H2 / Class A2 (C3)
- Brake chopper: No brake chopper
- Control panel: No local control panel
- PCB coating: Not coated
- Mains option: No mains option
- Adaptation A: Metric thread cable entry
- Adaptation B: No adaptation
- Net weight: approx. 7.3 kg
- Gross weight: approx. 8.05 kg
- EAN: 5702427940109
Reliable Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss VLT® HVAC Drive FC-102 regulate motor speed by adjusting the voltage and frequency supplied to the motor. This allows HVAC systems to match output to real demand, helping reduce energy usage, improve comfort control and minimise mechanical stress on driven equipment.
The FC-102 series is purpose-built for HVAC engineers, building services contractors and facility managers. Its application-focused features, integrated filtering and robust enclosure design make it a practical choice for ventilation, pumping, refrigeration and energy efficiency projects.
Typical Applications
- Air handling units and ventilation systems.
- Small supply and extract fans.
- Heating and chilled water circulation pumps.
- Commercial refrigeration systems.
- Building management and automation systems.
- Energy efficiency upgrades in commercial facilities.
Frequently Asked Questions
What is the Danfoss 131U2928 used for?
The Danfoss 131U2928 is used to control the speed of three-phase motors in HVAC, ventilation, heating, cooling and refrigeration applications.
What motor power is supported by this drive?
This drive provides a rated output power of approximately 1.5 kW / 2.0 HP.
What supply voltage does the drive require?
The Danfoss 131U2928 operates from a three-phase 380–480 V AC supply.
What enclosure rating does this drive have?
The drive features an IP55 / Type 12 enclosure, making it suitable for demanding HVAC and building services environments.
Does this model include a local control panel?
No, this configuration is supplied with no local control panel.
Trusted by HVAC Professionals Worldwide
Danfoss VLT® HVAC Drive FC-102 frequency converters are widely used by building services engineers, HVAC specialists and facility managers to deliver reliable motor control, energy efficiency and long-term operational performance.
| Manufacturer Part Number | 131U2928 |
|---|---|
| Barcode | 5702427940109 |
| Height | 390mm |
| Width | 200mm |
| Depth | 175mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 1.5kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P1K5T4Z55H2XXXXOXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.