Why Choose the Danfoss 131N1095 VLT® HVAC Drive FC-102?
The Danfoss 131N1095 is a robust and energy-efficient AC variable frequency drive (VFD) designed for accurate motor speed control in heating, ventilation, air conditioning and refrigeration systems. As part of the trusted Danfoss VLT® HVAC Drive FC-102 series, it is engineered for HVAC contractors, building services engineers and industrial users who require dependable performance, efficient operation and flexible installation.
This drive is purpose-built for HVAC applications, helping optimise the operation of fans, pumps, compressors and ventilation equipment. By matching motor speed to real system demand, the FC-102 series helps reduce energy consumption, improve process stability and minimise mechanical wear across connected equipment.
With a rated output power of 11 kW / 15 HP and a three-phase 380–480 V AC supply, the Danfoss 131N1095 is suitable for medium-duty commercial and industrial HVAC motor control. Its IP55 / Type 12 backplate enclosure and integrated mains disconnect make it suitable for demanding plant room and building services installations.
Key Advantages
- Dedicated variable frequency drive for HVAC applications.
- 11 kW / 15 HP motor power rating for fans, pumps and ventilation systems.
- Three-phase 380–480 V AC input suitable for industrial and commercial supplies.
- IP55 / Type 12 backplate enclosure for enhanced environmental protection.
- Integrated RFI Class A1/B (C1) filtering for EMC performance.
- Supplied with mains disconnect for convenient local isolation.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 11 kW / 15 HP rated output power.
- Three-phase 380–480 V AC input supply.
- IP55 / Type 12 backplate enclosure protection.
- Frame size B1.
- RFI Class A1/B (C1) EMC filter.
- Graphical local control panel fitted.
- Mains disconnect included.
- No brake chopper included.
- Latest standard software and no additional A, B, C1 or D options.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: FC-102P11KT4P55H1XGX1OXSXXXXAXBXCXXXXDX
- SKU / Code number: 131N1095
- Product type: AC variable frequency drive
- Rated output power: 11 kW / 15 HP
- Input voltage: 380–480 V AC
- Input phases: 3-phase
- Output phases: 3-phase
- Frequency: 50 / 60 Hz
- Protection rating: IP55 / Type 12 backplate
- Mounting type: Wall / panel mounting
- Frame size: B1
- RFI filter: Class A1/B (C1)
- Brake chopper: Not included
- Local control panel: Graphical local control panel
- PCB coating: Not coated
- Mains option: Mains disconnect
- A option: No A option
- B option: No B option
- C1 option: No C1 option
- D option: No D option
- Software: Latest release standard software
- Dimensions (H × W × D): approx. 494 × 243 × 261 mm
Efficient Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss 131N1095 regulate motor speed by adjusting output voltage and frequency. This enables HVAC equipment to operate according to real load demand, helping reduce unnecessary energy use while improving system control and equipment lifetime.
The FC-102 series is designed specifically for ventilation, heating, air conditioning and refrigeration applications. Its HVAC-focused functions, graphical control interface, EMC filtering and mains disconnect option make it a practical choice for plant rooms, building automation systems and industrial facilities.
Typical Applications
- Air handling units and ventilation systems.
- HVAC fan speed control.
- Chilled water and condenser pumps.
- Cooling towers and refrigeration systems.
- Commercial building services.
- Industrial heating, cooling and process air systems.
Frequently Asked Questions
What is the Danfoss 131N1095 used for?
The Danfoss 131N1095 is used to control the speed and torque of three-phase AC motors in HVAC systems, including fans, pumps, ventilation units and refrigeration equipment.
What motor power does this drive support?
This drive supports motors with a rated output power of approximately 11 kW / 15 HP.
What supply voltage does the drive require?
The Danfoss 131N1095 operates from a three-phase 380–480 V AC supply.
What enclosure rating does this model have?
This model has an IP55 / Type 12 backplate enclosure, providing enhanced protection for commercial and industrial environments.
Does the Danfoss 131N1095 include a mains disconnect?
Yes, this configuration is supplied with a mains disconnect for convenient local isolation.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC Drive FC-102 units are widely used by building services engineers, HVAC contractors and industrial facilities to deliver reliable motor control, improved energy efficiency and long-term system performance.
| Manufacturer Part Number | 131N1095 |
|---|---|
| Barcode | 5702427819900 |
| Height | 494mm |
| Width | 243mm |
| Depth | 261mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 11kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P11KT4P55H1XGX1OXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.