131H7550 Danfoss VLT FC-102 HVAC Drive 5.5 KW / 7.5 HP, 380 - 480 VAC, IP55
MPN: 131H7550
Alt. SKU: FC-102P5K5T4P55H3XXX1XXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 131H7550 VLT HVAC Drive?
The Danfoss 131H7550 is a dependable VLT® HVAC Drive FC-102 designed for efficient speed control of three-phase motors in heating, ventilation, air conditioning and refrigeration applications. Built for HVAC environments, this drive helps optimise motor performance, improve energy efficiency and provide reliable control for essential building services equipment.
As part of the Danfoss VLT FC-102 HVAC drive series, the 131H7550 offers dedicated functionality for pumps, fans and compressors. It is engineered to support accurate airflow, pressure and process control while helping reduce energy usage and mechanical wear across modern HVAC systems.
With a rated output power of 5.5 kW / 7.5 HP, a three-phase 380-480 V AC supply and an IP55 / Type 12 enclosure, this drive is well suited to demanding commercial, industrial and building automation installations where robust protection and reliable motor control are required.
Key Advantages
- Dedicated HVAC variable frequency drive for fans, pumps and compressors.
- 5.5 kW / 7.5 HP power rating for larger HVAC motor control applications.
- Three-phase 380-480 V AC input compatible with industrial and commercial power systems.
- IP55 / Type 12 enclosure for enhanced protection in demanding installations.
- Integrated RFI Class A1/B (C1) filtering to support EMC performance.
- Mains disconnect included for practical installation and maintenance access.
- Designed to help reduce energy consumption and improve HVAC system efficiency.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 5.5 kW / 7.5 HP rated output power.
- Three-phase 380-480 V AC supply voltage.
- IP55 / Type 12 enclosure protection.
- Frame size A5.
- RFI Class A1/B (C1) filter.
- Mains disconnect included.
- No brake chopper and no local control panel fitted.
- Standard cable entries and latest standard software.
- Designed for ventilation, heating and refrigeration applications.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: FC-102P5K5T4P55H3XXX1XXSXXXXAXBXCXXXXDX
- SKU / Code number: 131H7550
- Product type: AC variable frequency drive
- Rated output power: 5.5 kW / 7.5 HP
- Input voltage: 380-480 V AC
- Input phases: Three phase
- Output phases: Three phase
- Protection rating: IP55 / Type 12
- Frame size: A5
- RFI filter: Class A1/B (C1)
- Brake chopper: Not included
- Local control panel: Not included
- PCB coating: Not coated
- Mains option: Mains disconnect
- A option: No A option
- B option: No B option
- C1 option: No C1 option
- D option: No D option
- Cable entry: Standard cable entries
- Software: Latest release standard software
Reliable Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss VLT HVAC Drive FC-102 regulate motor speed by adjusting output frequency and voltage. This allows HVAC equipment to match motor output to actual demand, helping reduce unnecessary energy use while supporting smoother and more efficient operation.
The 131H7550 is ideal for HVAC engineers, facilities managers and building services contractors who need reliable speed control for essential plant equipment. Its dedicated fan, pump and compressor functions make it suitable for modern buildings where comfort, efficiency and dependable operation are key priorities.
Typical Applications
- HVAC fan speed control.
- Air handling units and ventilation systems.
- Building services pump control.
- Heating and cooling plant equipment.
- Refrigeration and compressor applications.
- Commercial buildings and facilities management.
- Industrial HVAC and process ventilation systems.
Frequently Asked Questions
What is the Danfoss 131H7550 used for?
The Danfoss 131H7550 is used to control the speed of three-phase motors in HVAC applications such as fans, pumps, compressors and building services equipment.
What power rating does this drive have?
This drive has a rated output power of 5.5 kW / 7.5 HP.
What supply voltage does the 131H7550 require?
The Danfoss 131H7550 operates from a three-phase 380-480 V AC supply.
What enclosure rating does this drive have?
The drive has an IP55 / Type 12 enclosure, making it suitable for protected HVAC and building services installations.
Does this model include a mains disconnect?
Yes. This configuration includes a mains disconnect.
Trusted by HVAC Engineers Worldwide
Danfoss VLT HVAC drives are widely used by building services engineers, facilities teams and HVAC specialists to deliver efficient motor control, dependable system operation and reduced energy consumption in modern buildings.
| Manufacturer Part Number | 131H7550 |
|---|---|
| Barcode | 5702427580169 |
| Height | 420mm |
| Width | 242mm |
| Depth | 200mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 5.5kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P5K5T4P55H3XXX1XXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.