We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
131G5727 Danfoss VLT FC-102 HVAC Drive 37 KW / 50 HP, 380 - 480 VAC, IP55
MPN: 131G5727
Alt. SKU: FC-102P37KT4E55H1XNXXXXSXXXXA0BXCXXXXDX
Why Choose the Danfoss 131G5727 VLT® HVAC Drive FC-102?
The Danfoss 131G5727 is a reliable and efficient AC variable frequency drive (VFD) designed for precise speed control of three-phase motors in heating, ventilation, air conditioning and refrigeration systems. As part of the trusted Danfoss VLT® HVAC Drive FC-102 series, it is engineered to improve HVAC performance, reduce energy consumption and support dependable operation in commercial and industrial environments.
This drive combines dedicated HVAC functionality with proven Danfoss motor control technology. It is suitable for pumps, fans, compressors and air handling equipment, helping engineers optimise system demand while reducing mechanical stress and operating costs.
With a rated output power of 37 kW / 50 HP and a three-phase 380–480 V AC supply, the Danfoss 131G5727 is ideal for medium to large HVAC motor control applications. Its IP55 / Type 12 enclosure provides enhanced protection for demanding installations, while the integrated PROFIBUS DP MCA 101 option supports connection to compatible automation and building management networks.
Key Advantages
- Dedicated VLT® HVAC Drive FC-102 frequency converter for HVAC motor control.
- 37 kW / 50 HP power rating suitable for pumps, fans and compressors.
- Three-phase 380–480 V AC input compatible with industrial and commercial power systems.
- IP55 / Type 12 enclosure for improved protection in demanding installations.
- Integrated RFI Class A1/B (C1) filter to support EMC requirements.
- PROFIBUS DP MCA 101 option for integration with compatible automation networks.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 37 kW / 50 HP rated output power.
- Three-phase 380–480 V AC mains voltage.
- IP55 / Type 12 enclosure.
- Integrated RFI Class A1/B (C1) filter.
- No brake chopper.
- Numerical local control panel fitted.
- PROFIBUS DP MCA 101 A option.
- No B option.
- Not coated PCB.
- Frame size C1 construction.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: 131G5727
- Model code: FC-102P37KT4E55H1XNXXXXSXXXXA0BXCXXXXDX
- Product type: Frequency converter / variable frequency drive
- Rated output power: 37 kW / 50 HP
- Input voltage: 380–480 V AC
- Input phases: Three phase
- Frequency: 50 / 60 Hz
- Protection rating: IP55 / Type 12
- Mounting type: Wall / backplate mounting
- Frame size: C1
- RFI filter: Class A1/B (C1)
- Brake option: No brake chopper
- Control panel: Numerical local control panel
- PCB coating: Not coated PCB
- Mains option: No mains option
- A option: PROFIBUS DP MCA 101
- B option: No B option
- C1 option: No C1 option
- D option: No D option
Efficient Motor Control for HVAC Systems
Variable frequency drives such as the Danfoss FC-102 regulate motor speed by adjusting output voltage and frequency to match real system demand. This helps reduce unnecessary energy use, improve process stability and minimise mechanical wear on motors and connected HVAC equipment.
The FC-102 HVAC drive series is designed specifically for ventilation, heating and refrigeration applications. With dedicated HVAC functions, fieldbus communication options and dependable motor control, the Danfoss 131G5727 is well suited to building services, plant rooms and industrial climate control systems.
Typical Applications
- HVAC pumps and circulation systems.
- Supply and extract ventilation fans.
- Air handling units (AHUs).
- Compressors and refrigeration equipment.
- Heating and cooling systems.
- Building management systems (BMS).
- Industrial ventilation and environmental control systems.
Frequently Asked Questions
What is the Danfoss 131G5727 used for?
The Danfoss 131G5727 is used to control the speed and performance of three-phase AC motors in HVAC, pump, fan, compressor and refrigeration applications.
What motor power is supported by this drive?
This drive is rated for motors up to approximately 37 kW / 50 HP.
What supply voltage does the drive require?
The 131G5727 operates from a three-phase 380–480 V AC supply.
Does this model include a communication option?
Yes, this version includes the PROFIBUS DP MCA 101 option for fieldbus communication with automation and building management systems.
Where is this drive typically installed?
The IP55 / Type 12 enclosure is designed for protected wall or backplate installation in suitable commercial and industrial environments.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC Drive FC-102 frequency converters are widely used by engineers, facility managers and system integrators to deliver reliable motor control, energy-efficient HVAC operation and long-term system performance.
| Manufacturer Part Number | 131G5727 |
|---|---|
| Barcode | 5702427664111 |
| Height | 685mm |
| Width | 308mm |
| Depth | 311mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 37kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P37KT4E55H1XNXXXXSXXXXA0BXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.