Do you need some help?

Call us now on: 01706 242050

131F0340 Danfoss VLT FC-102 HVAC Drive 45 KW / 60 HP, 380 - 480 VAC, IP20

MPN: 131F0340

Alt. SKU: FC-102P45KT4E20H1XGXXXXSXXXXAXBXCXXXXDX

Special Price £3,855.60 £3,213.00 Regular Price £6,426.00

Please contact us for a delivery time
Call us now on 01706 242050

Need It Today?

Speak To Our Team

Speak to our experienced team to discuss options for getting your order to you today.

or

Call us now on: 01706 242050
  • Please ensure the items you would like are in stock
  • Please speak to our team before placing an order
  • Additional charges will apply
  • We cannot guarantee the availability of a courier

Found It Cheaper?

Please complete the form below or call us now on 01706 242050

Free delivery on orders over £200

Why Choose the Danfoss 131F0340 VLT HVAC Drive FC 102?

The Danfoss 131F0340 is a powerful and efficient AC variable frequency drive (VFD) from the Danfoss VLT® HVAC Drive FC 102 series, designed for precise speed control of three-phase AC motors in heating, ventilation, air conditioning, pump and fan applications. Developed specifically for HVAC systems, this drive helps reduce energy consumption, improve motor performance and support stable operation in commercial, industrial and building services environments.

As part of the Danfoss VLT HVAC Drive FC 102 range, the 131F0340 provides application-focused motor control in a robust cabinet-mounted format. Its integrated RFI Class A1/B (C1) filter, IP20 chassis design and standard HVAC control functionality make it suitable for electrical control panels where dependable operation, energy efficiency and repeatable commissioning are essential.

With a rated output power of 45 kW / 60 HP and a three-phase 380-480 V AC supply, the Danfoss 131F0340 is ideal for larger HVAC motors, pumps, fans and compressors requiring accurate variable speed control. This configuration includes a graphical local control panel, is supplied with no brake chopper and uses a C3 frame size for cabinet installation.

Key Advantages

  • Dedicated variable frequency drive for HVAC, pump and fan applications.
  • 45 kW / 60 HP output power rating for demanding building services and industrial motor control systems.
  • Three-phase 380-480 V AC input suitable for industrial and commercial power systems.
  • 90 A continuous normal overload current at 380-440 V AC for compatible three-phase motor systems.
  • Graphical local control panel for easier commissioning, monitoring and parameter access.
  • Integrated RFI Class A1/B (C1) filter to support EMC requirements.

Key Features

  • Danfoss VLT® HVAC Drive FC 102 series.
  • 45 kW rated output power.
  • 60 HP motor power rating.
  • 90 A continuous normal overload current at 380-440 V AC.
  • Three-phase 380-480 V AC input supply.
  • Three-phase motor output.
  • IP20 / chassis protection rating.
  • Built-in RFI Class A1/B (C1) filter.
  • Graphical local control panel included.
  • No brake chopper supplied.
  • C3 frame size for cabinet mounting.

Technical Specifications

  • Manufacturer: Danfoss
  • Series: VLT® HVAC Drive FC 102
  • Model: 131F0340
  • Type code: FC-102P45KT4E20H1XGXXXXSXXXXAXBXCXXXXDX
  • Product type: AC variable frequency drive / frequency converter
  • Rated output power: 45 kW / 60 HP
  • Continuous current: 90 A normal overload / 80 A normal overload
  • Intermittent current: 99 A normal overload / 88 A normal overload
  • Input voltage: 380-480 V AC
  • Input phases: 3-phase
  • Output phases: 3-phase
  • Input frequency: 50 / 60 Hz
  • kVA rating: 62.4 kVA
  • Power loss: approx. 843 W
  • Protection rating: IP20 / chassis
  • RFI filter: Class A1/B (C1)
  • Brake chopper: No
  • Local control panel: Graphical local control panel
  • PCB: Not coated
  • Mains option: No mains option
  • A option: No A option
  • B option: No B option
  • C1 option: No C1 option
  • D option: No D option
  • Software: Latest release standard software
  • Mounting type: Panel / cabinet mounting
  • Frame size: C3
  • Dimensions (H x W x D): approx. 550 x 308 x 333 mm
  • Net weight: approx. 35.69 kg
  • Gross weight: approx. 38.54 kg

Efficient Motor Control for HVAC Systems

Variable frequency drives such as the Danfoss 131F0340 regulate motor speed by adjusting the output voltage and frequency supplied to the motor. This allows pumps, fans and compressors to operate at the required speed rather than continuously running at full output, helping reduce energy consumption, noise and mechanical wear.

The VLT HVAC Drive FC 102 series is designed around the needs of heating, ventilation and air conditioning systems, with control functionality that supports efficient fan operation, pump control and building services performance. Its robust C3 chassis format, integrated EMC filtering and graphical local control panel make it a practical choice for control panel manufacturers, facilities engineers and maintenance teams.

Typical Applications

  • HVAC fan and ventilation systems.
  • Pump control and pressure regulation.
  • Air handling units and building services equipment.
  • Compressors and refrigeration-related motor systems.
  • Commercial and industrial HVAC installations.
  • General three-phase motor speed control in control panels.

Frequently Asked Questions

What is the Danfoss 131F0340 used for?

The Danfoss 131F0340 is used to control the speed of three-phase AC motors in HVAC, pump, fan, compressor and building services applications.

What power rating does the Danfoss 131F0340 support?

This drive has a rated output power of approximately 45 kW / 60 HP.

What supply voltage does the Danfoss 131F0340 require?

The 131F0340 operates from a three-phase 380-480 V AC supply.

Does the Danfoss 131F0340 include a local control panel?

Yes, this configuration includes a graphical local control panel for commissioning, monitoring and parameter access.

Does the Danfoss 131F0340 include a brake chopper?

No, this specific configuration is supplied with no brake chopper.

Trusted by HVAC and Automation Engineers

Danfoss VLT HVAC Drive FC 102 frequency converters are widely used by building services engineers, panel builders and maintenance teams for efficient fan, pump and compressor motor control.
More Information
Manufacturer Part Number 131F0340
Barcode 5702427396012
Height 550mm
Width 308mm
Depth 333mm
Filter Filter Included
Input Phases Three Phase
Degree of protection (IP) IP20
KW Rating 45kW
Output Phases Three phase
VSD Range Danfoss VLT FC102
Manufacturer Danfoss
Alternative Product SKU FC-102P45KT4E20H1XGXXXXSXXXXAXBXCXXXXDX
Write Your Own Review
You're reviewing:131F0340 Danfoss VLT FC-102 HVAC Drive 45 KW / 60 HP, 380 - 480 VAC, IP20

The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.

The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.

Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.

Supply voltages and power range

3 x 200-240 V...1.1-45 kW

3 x 380-480 V...1.1 kW – 1 MW

3 x 525-600 V...1.1-90 kW

3 x 525-690 V...45 kW – 1.4 MW

Low harmonic drive

3 x 380-480 V...132-710 kW

12-pulse drive

3 x 380-480 V...250-200kW

Features and benefits

  • There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
  • PLC capacity is often unnecessary thanks to the Smart Logic Controller 
  • A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
  • The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
  • 5–15% energy is saved as a result of the Automatic Energy Optimization function
  • Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity

 

Applications

Pumps, fans, compressors.

PC tools

VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box

For further information on this product please get in touch with our team or visit the Danfoss website.