We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
131B8586 Danfoss VLT FC-102 HVAC Drive 37 KW / 50 HP, 380 - 480 VAC, IP55
MPN: 131B8586
Alt. SKU: FC-102P37KT4P55H3XGX1XXSXXXXAXBXCXXXXDX
Why Choose the Danfoss 131B8586 VLT® HVAC Drive FC-102?
The Danfoss 131B8586 is a powerful and energy-efficient AC variable speed drive (VSD) designed for precise motor control in heating, ventilation and air conditioning applications. As part of the proven Danfoss VLT® HVAC Drive FC-102 series, it is engineered to optimise the performance of fans, pumps, compressors and refrigeration equipment in commercial and industrial environments.
This drive provides accurate frequency control while helping reduce energy consumption, improve system stability and minimise mechanical wear. The FC-102 range includes dedicated HVAC functionality, flexible configuration options and a graphical local control panel for straightforward commissioning, monitoring and everyday operation.
With a rated output power of 37 kW (50 HP) and a three-phase 380–480 V AC supply, the Danfoss 131B8586 is ideal for demanding HVAC motors requiring dependable speed regulation. Its IP55 / Type 12 backplate enclosure provides reliable protection for plant rooms and industrial environments where dust and moisture resistance are required.
Key Advantages
- Dedicated variable speed drive for HVAC applications.
- 37 kW / 50 HP motor power rating for larger pumps, fans and ventilation systems.
- Three-phase 380–480 V AC input for commercial and industrial installations.
- IP55 / Type 12 backplate enclosure for protected operation in demanding environments.
- Integrated mains disconnect for safer isolation and maintenance.
- Graphical local control panel for setup, monitoring and operation.
Key Features
- Danfoss VLT® HVAC Drive FC-102 series.
- 37 kW / 50 HP rated output power.
- 73 A / 65 A continuous output current.
- 80.3 A / 71.5 A intermittent output current.
- Three-phase 380–480 V AC input supply.
- IP55 / Type 12 backplate enclosure rating.
- H3 RFI Class A1/B (C1) filter.
- Frame size C1 construction.
Technical Specifications
- Manufacturer: Danfoss
- Series: VLT® HVAC Drive FC-102
- Model: FC-102P37KT4P55H3XGX1XXSXXXXAXBXCXXXXDX
- SKU: 131B8586
- Product type: Variable speed drive / frequency converter
- Rated output power: 37 kW / 50 HP
- Input voltage: 380–480 V AC
- Input phases: 3-phase
- kVA rating: 50.6 kVA
- Continuous output current: 73 A / 65 A
- Intermittent output current: 80.3 A / 71.5 A
- Power loss: 739 W
- Protection rating: IP55 / Type 12 Backplate
- RFI filter: H3, RFI Class A1/B (C1)
- Brake chopper: No brake chopper
- Control panel: Graphical local control panel
- PCB coating: Not coated PCB
- Mains option: Mains disconnect
- Software: Latest release standard software
- Frame size: C1
Efficient Motor Control for HVAC Systems
Variable speed drives such as the Danfoss FC-102 control motor speed by adjusting output voltage and frequency. This enables HVAC equipment to operate according to actual demand, helping reduce wasted energy while improving comfort control and system reliability.
The FC-102 series is designed specifically for HVAC duty, with application-focused functions for fans, pumps, compressors and refrigeration equipment. Its IP55 enclosure, integrated filtering and user-friendly graphical interface make the 131B8586 suitable for contractors, building services engineers and facility managers seeking dependable long-term performance.
Typical Applications
- Air handling units and large ventilation systems.
- HVAC pumps and circulating systems.
- Fan speed control in commercial buildings.
- Cooling and refrigeration equipment.
- Plant room motor control systems.
- Industrial heating, ventilation and refrigeration applications.
Frequently Asked Questions
What is the Danfoss 131B8586 used for?
The Danfoss 131B8586 is used to control AC motor speed in HVAC applications such as fans, pumps, compressors, ventilation systems and refrigeration equipment.
What motor power does this drive support?
This drive supports motors with a rated output power of approximately 37 kW / 50 HP.
What supply voltage does the Danfoss 131B8586 require?
The drive operates from a three-phase 380–480 V AC supply.
What enclosure rating does this drive have?
The 131B8586 has an IP55 / Type 12 backplate enclosure, providing protection for plant room and industrial HVAC installations.
Does the Danfoss 131B8586 include a mains disconnect?
Yes, this drive includes a mains disconnect option for safer isolation and maintenance access.
Trusted by HVAC Engineers Worldwide
Danfoss VLT® HVAC Drives are widely used by building services engineers, facility managers and industrial contractors to deliver efficient motor control, dependable operation and reduced energy consumption across HVAC installations.
| Manufacturer Part Number | 131B8586 |
|---|---|
| Barcode | 5702427374577 |
| Height | 680mm |
| Width | 308mm |
| Depth | 310mm |
| Filter | Filter Included |
| Input Phases | Three Phase |
| Degree of protection (IP) | IP55 |
| KW Rating | 37kW |
| Output Phases | Three phase |
| VSD Range | Danfoss VLT FC102 |
| Manufacturer | Danfoss |
| Alternative Product SKU | FC-102P37KT4P55H3XGX1XXSXXXXAXBXCXXXXDX |
The VLT HVAC drive has built-in intelligence to give optimal process control to heating, ventilation and air conditioning (HVAC). It is simple to use and extremely cost-efficient, featuring a number of functions that are ideal for use with pumps, fans and compressors to save energy, meet environmental regulations and reduce costs in modern buildings.
The VLT HVAC drive has a compact, robust design and is ideally suited to locations where space is restricted. A selection of safety features, such as Safe Torque Off and Safe Maximum Speed, protect both applications and their operators.
Enclosures can be purchased separately, up to IP66, and an additional option available upon purchase is a unique coating to provide added protection for the circuit boards. Integrated DC chokes and RFI filters safeguard installations by minimizing harmonic distortion and electromagnetic.
Supply voltages and power range
3 x 200-240 V...1.1-45 kW
3 x 380-480 V...1.1 kW – 1 MW
3 x 525-600 V...1.1-90 kW
3 x 525-690 V...45 kW – 1.4 MW
Low harmonic drive
3 x 380-480 V...132-710 kW
12-pulse drive
3 x 380-480 V...250-200kW
Features and benefits
- There’s no need for external cooling or oversizing as the maximum ambient temperature is 50°C without derating
- PLC capacity is often unnecessary thanks to the Smart Logic Controller
- A low initial investment and easy upgrades are possible thanks to the modular concept with a wide range of options
- The need for external control and conversion equipment is avoided due to integrated pump, fan and compressor functionality
- 5–15% energy is saved as a result of the Automatic Energy Optimization function
- Less gateway solutions are needed thanks to a wide range of HVAC protocols for building management system controller connectivity
Applications
Pumps, fans, compressors.
PC tools
VLT® Motion Control Tool MCT 10
VLT® Motion Control Tool MCT 31
Danfoss ecoSmart
Danfoss HCS (Harmonic Calculation Software)
Danfoss Servo Sizer
VLT® Energy Box
For further information on this product please get in touch with our team or visit the Danfoss website.