SP2-40K275V Mersen Type 2 1P 230V Replacement Cartridge

SP2-40K275V Mersen Type 2 1P 230V Replacement Cartridge

Mersen 83020002 SP2-40K275V Type 2 surge protection replacement cartridge with 40 kA maximum discharge current, 20 kA nominal discharge current and 275 V AC maximum continuous operating voltage for compatible Surge-Trap devices.

SKU: 83020002Alt SKU: SP2-40K275VMPN: 83020002
This product has been discontinued A direct replacement is available below.
K2-275 Mersen Type 2 1P 230V Replacement Cartridge Replacement product K2-275 Mersen Type 2 1P 230V Replacement Cartridge SKU: 44020001 £22.22 ex VAT View

Why Choose the Mersen 83020002 Type 2 Replacement Cartridge?

The Mersen 83020002, also known as SP2-40K275V, is a reliable Type 2 surge protection replacement cartridge designed for compatible Mersen Surge-Trap pluggable surge protection devices. It helps protect electrical installations against transient overvoltages caused by switching operations, indirect lightning effects and power network disturbances.

As part of the Mersen Surge-Trap STP T2 40 series, this replacement cartridge is suitable for low-voltage distribution systems where coordinated surge protection is required. Its plug-in design allows fast replacement during maintenance, helping reduce downtime while restoring protection to the surge protection assembly.

With a 40 kA maximum discharge current, 20 kA nominal discharge current and 275 V AC maximum continuous operating voltage, the Mersen 83020002 is a practical choice for Type 2 SPD applications on 230 V electrical systems.

Key Advantages

  • Type 2 / Class II surge protection replacement cartridge for compatible Mersen Surge-Trap devices.
  • 40 kA maximum discharge current for robust transient overvoltage protection.
  • 20 kA nominal discharge current for reliable surge handling performance.
  • 275 V AC maximum continuous operating voltage for 230 V systems.
  • Plug-in cartridge format supports quick replacement and reduced maintenance time.
  • Suitable for distribution panels, control panels and low-voltage electrical systems.

Key Features

  • Mersen Surge-Trap STP T2 40 series.
  • Type 2 / Class II surge protection.
  • Replacement cartridge format.
  • 1 pole configuration.
  • 230 V AC nominal voltage.
  • 275 V AC maximum continuous operating voltage.
  • 40 kA maximum discharge current.
  • 20 kA nominal discharge current.

Reliable Type 2 Surge Protection for Distribution Systems

Type 2 surge protection devices are commonly installed in distribution boards and sub-distribution panels to limit transient overvoltages before they reach connected electrical equipment. They are often used as the second stage of protection where Type 1 devices are installed upstream, or as the first stage in installations without direct lightning exposure.

The Mersen 83020002 replacement cartridge enables maintenance teams to restore surge protection quickly without replacing the complete SPD base. This makes it suitable for panel builders, electrical contractors and facilities engineers maintaining commercial and industrial electrical systems.

Typical Applications

  • 230 V low-voltage electrical systems.
  • Electrical distribution boards.
  • Commercial building services panels.
  • Industrial control panels and switchboards.
  • Sub-distribution surge protection systems.
  • Maintenance replacement for compatible Mersen Surge-Trap devices.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 275 V
Phase Single Phase
Poles 1-pole
Device Type Replacement cartridge
SPD Type Type 2
Nominal Discharge Current (In) 20 kA
Manufacturer Mersen
Series Surge-Trap STP T2 40
Model SP2-40K275V
Manufacturer part number 83020002
Product type Surge protection replacement cartridge
SPD classification Type 2 / Class II
Number of poles 1 pole
Nominal voltage 230 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Nominal discharge current (In) 20 kA
Maximum discharge current (Imax) 40 kA
Protection rating IP20
Mounting Pluggable replacement cartridge
Compatible installation DIN rail SPD assembly

Frequently Asked Questions

What is the Mersen 83020002 used for?

The Mersen 83020002 is a Type 2 replacement cartridge for compatible Mersen Surge-Trap surge protection devices used in low-voltage electrical distribution systems.

What is the alternative product code?

The alternative product code for Mersen 83020002 is SP2-40K275V.

What voltage is this cartridge rated for?

This replacement cartridge is designed for 230 V AC nominal systems and has a 275 V AC maximum continuous operating voltage.

What surge protection type does this cartridge provide?

The Mersen 83020002 is designed for Type 2 / Class II surge protection assemblies.

Where is this replacement cartridge typically installed?

It is typically installed in compatible Mersen Surge-Trap pluggable SPD assemblies within distribution boards, switchboards and control panels.

Trusted by Electrical Engineers Worldwide

Mersen Surge-Trap surge protection products are widely used by electrical engineers, panel builders and contractors to protect commercial and industrial electrical installations from damaging transient overvoltages.