K2-275 Mersen Type 2 1P 230V Replacement Cartridge

K2-275 Mersen Type 2 1P 230V Replacement Cartridge

Mersen 44020001 K2-275 Type 2 replacement cartridge for compatible Surge-Trap K2 Series surge protection devices, featuring 275 V AC maximum continuous operating voltage, 20 kA nominal discharge current and 50 kA maximum discharge current.

SKU: 44020001Alt SKU: K2-275MPN: 44020001
Price
List Price £29.62 ex VAT
Your Price (ex VAT) Save 25%
£22.22 25% OFF
You save £7.41 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £22.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£22.22

Why Choose the Mersen 44020001 K2-275 Replacement Cartridge?

The Mersen 44020001, also known as the K2-275, is a genuine Type 2 surge protection replacement cartridge for compatible Mersen Surge-Trap® K2 Series surge protection devices. Designed for the rapid restoration of surge protection without replacing the complete SPD assembly, this pluggable single-pole module offers a cost-effective maintenance solution for commercial and industrial electrical installations.

The K2-275 is designed for 230 V AC systems with a 275 V AC maximum continuous operating voltage (Uc). It provides a 20 kA nominal discharge current and a 50 kA maximum discharge current, delivering dependable protection against transient overvoltages caused by indirect lightning strikes and electrical switching events.

Its reinforced pluggable construction allows replacement within seconds while leaving the original DIN rail base and wiring intact. An integrated visual status indicator makes routine inspections simple, helping maintenance engineers identify when replacement is required.

Key Advantages

  • Genuine replacement cartridge for compatible Mersen Surge-Trap® K2 Series SPDs.
  • Type 2 / Class II surge protection.
  • 50 kA maximum discharge current for effective transient protection.
  • 20 kA nominal discharge current for reliable long-term performance.
  • 275 V AC maximum continuous operating voltage.
  • Single-pole pluggable cartridge enables rapid replacement.
  • Visual operational status indicator simplifies maintenance.
  • Reduces downtime by eliminating the need to replace the complete SPD.

Key Features

  • Mersen Surge-Trap® K2 Series.
  • K2-275 replacement cartridge.
  • Type 2 / IEC Class II surge protection.
  • Single-pole replacement module.
  • 230 V AC nominal system voltage.
  • 275 V AC maximum continuous operating voltage (Uc).
  • 20 kA nominal discharge current (In).
  • 50 kA maximum discharge current (Imax).
  • Visual end-of-life indication.
  • Reinforced pluggable construction.

Fast Maintenance for Surge Protection Systems

Surge protection devices absorb transient energy throughout their service life and eventually require replacement after repeated surge events. The Mersen K2-275 replacement cartridge enables maintenance engineers to restore protection quickly without disconnecting wiring or replacing the complete surge protection assembly.

Its modular design reduces maintenance costs and minimises system downtime, making it ideal for industrial plants, commercial buildings and critical infrastructure where continuous electrical protection is essential.

Typical Applications

  • Replacement cartridge for compatible Mersen K2 Series SPDs.
  • Industrial distribution boards.
  • Commercial switchboards.
  • Automation and PLC control panels.
  • Building services installations.
  • Manufacturing facilities.
  • Low-voltage power distribution systems.
  • Maintenance of surge protection installations.

Technical Specifications

Tick the specs you need, then view products that match.

Voltage 230 V
Phase Single Phase
Poles 1-pole
Device Type Replacement cartridge
SPD Type Type 2
Nominal Discharge Current (In) 20 kA
Manufacturer Mersen
Series Surge-Trap® K2 Series
Model K2-275
Manufacturer part number 44020001
Product type Replacement surge protection cartridge
SPD classification Type 2 / IEC Class II
Number of poles 1
Nominal system voltage 230 V AC
Maximum continuous operating voltage (Uc) 275 V AC
Nominal discharge current (In) 20 kA
Maximum discharge current (Imax) 50 kA
Surge waveform 8/20 µs
Format Pluggable replacement cartridge
Mounting Compatible K2 DIN rail surge protection base
Status indication Visual operational indicator
Maximum back-up fuse 315 A
Operating temperature -40 to +85 °C
Protection rating IP20
RoHS compliant Yes

Frequently Asked Questions

What is the Mersen 44020001 used for?

The Mersen 44020001 is a genuine K2-275 replacement cartridge designed to restore surge protection in compatible Mersen Surge-Trap® K2 Series devices.

Is the K2-275 a complete surge protection device?

No. It is a replacement cartridge that fits compatible Mersen K2 surge protection bases and is not a complete standalone SPD.

What surge current can the K2-275 withstand?

The cartridge provides a nominal discharge current of 20 kA and a maximum discharge current of 50 kA.

Can the cartridge be replaced without removing the DIN rail base?

Yes. The pluggable design allows the replacement module to be exchanged while leaving the original surge protection base and wiring in place.

Which systems is the K2-275 designed for?

The K2-275 is designed for compatible 230 V AC Mersen Surge-Trap® K2 Series surge protection devices using a 275 V AC replacement cartridge.

Trusted Surge Protection from Mersen

Mersen Surge-Trap® K2 replacement cartridges help maintain reliable surge protection while reducing maintenance time and extending the service life of installed surge protection systems.