ABB XT3N 250 4 pole Normal MCCB Adjustable Thermal/Fixed Magnetic Release In=200A Ii=600A

ABB XT3N 250 4 pole Normal MCCB Adjustable Thermal/Fixed Magnetic Release In=200A Ii=600A

ABB 1SDA068263R1 XT3N 250 four-pole moulded case circuit breaker with 200 A thermomagnetic release, 600 A magnetic setting, fixed front terminals and fully rated neutral for industrial electrical protection.

SKU: 1SDA068263R1Alt SKU: XT3N 250 TMG 200-600 4p F F InN=100%MPN: 1SDA068263R1
Price
List Price £1,407.81 ex VAT
Your Price (ex VAT) Save 25%
£1,055.86 25% OFF
You save £351.95 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,055.86
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,055.86

Why Choose the ABB XT3N 250 TMG 200-600 4P F F InN=100% Moulded Case Circuit Breaker?

The ABB 1SDA068263R1 is a robust moulded case circuit breaker (MCCB) from the proven ABB SACE Tmax XT range, designed to protect low voltage electrical distribution systems against overload and short circuit faults. Built for industrial and commercial applications, it provides reliable protection for demanding power distribution environments.

This model features an XT3N 250 frame with a 200 A thermomagnetic release and 600 A magnetic setting. Its four-pole fixed construction includes front terminal connections and a fully rated neutral pole (InN=100%), making it suitable for three-phase systems where full neutral current capacity is required.

The ABB 1SDA068263R1 combines compact installation, dependable mechanical construction and trusted ABB protection technology. It is ideal for switchboards, distribution panels, generator protection, motor control centres and OEM electrical assemblies requiring reliable circuit protection.

Key Advantages

  • Reliable ABB SACE Tmax XT moulded case circuit breaker.
  • 200 A rated current with thermomagnetic protection.
  • Four-pole fixed design with front terminal connections.
  • Fully rated neutral pole (InN=100%) for enhanced system compatibility.
  • Provides protection against overloads and short circuits.
  • Compact XT3 frame supports efficient switchboard and control panel layouts.

Key Features

  • Manufacturer: ABB
  • SACE Tmax XT3N 250 moulded case circuit breaker.
  • Product ID: 1SDA068263R1.
  • Rated current: 200 A.
  • Four-pole (4P) configuration.
  • Fully rated neutral: InN=100%.
  • Thermomagnetic (TMG) trip unit.
  • Fixed front terminals for secure installation.

Reliable Protection for Low Voltage Distribution Systems

The ABB SACE Tmax XT range is engineered to deliver dependable circuit protection in compact electrical assemblies. The thermomagnetic release provides overload protection for sustained overcurrent conditions while the magnetic element responds rapidly to short circuit faults, helping reduce equipment damage and improve operational safety.

With a fully rated neutral pole, the 1SDA068263R1 is suitable for three-phase distribution systems where neutral loading must be properly managed. Its fixed front terminal design supports straightforward installation in switchboards, distribution panels and industrial control systems.

Typical Applications

  • Industrial power distribution systems.
  • Commercial electrical installations.
  • Switchboards and distribution panels.
  • Motor control centres.
  • Generator and transformer protection.
  • OEM machinery and automation panels.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Fixed
Application Generator protection
Current 200 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax XT
Model XT3N 250 TMG 200-600 4P F F InN=100%
Product ID 1SDA068263R1
EAN 8015644021696
Product type Moulded Case Circuit Breaker (MCCB)
Frame size XT3
Rated current (In) 200 A
Rated uninterrupted current (Iu) 250 A
Magnetic trip setting 600 A
Rated operational voltage Up to 690 V AC / 500 V DC
Breaking capacity 36 kA at 415 V AC
Frequency 50 / 60 Hz
Number of poles 4
Neutral rating Fully rated neutral, InN=100%
Trip unit Thermomagnetic (TMG)
Terminal type Fixed front terminals
Mounting type Fixed
Standards IEC 60947-2
Protection rating IP20
HS Code 85362090
Country of Manufacture Italy

Frequently Asked Questions

What is the ABB 1SDA068263R1 used for?

It is a moulded case circuit breaker used to protect low voltage electrical circuits against overloads and short circuits in industrial and commercial installations.

What is the rated current of this MCCB?

The ABB 1SDA068263R1 has a rated current of 200 A.

What does InN=100% mean?

InN=100% means the neutral pole is fully rated, allowing it to carry the same rated current as the phase poles.

How many poles does this circuit breaker have?

This model has a four-pole (4P) configuration for three-phase systems requiring neutral switching or protection.

What type of trip unit is fitted?

It is fitted with a thermomagnetic (TMG) release, providing overload and magnetic short circuit protection.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are trusted by panel builders, contractors and industrial engineers for dependable circuit protection, compact installation and long operational life.