1SDA067129R1 ABB RC Inst x XT3 4p F Residual Current Release

1SDA067129R1 ABB RC Inst x XT3 4p F Residual Current Release

ABB 1SDA067129R1 RC Inst is an 85–690 V AC instantaneous residual current release designed for fixed four-pole SACE Tmax XT3 moulded case circuit breakers.

SKU: 1SDA067129R1MPN: 1SDA067129R1
Price
List Price £1,167.32 ex VAT
Your Price (ex VAT) Save 25%
£875.49 25% OFF
You save £291.83 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £875.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£875.49

Why Choose the ABB RC Inst x XT3 4p F Residual Current Release?

The ABB RC Inst x XT3 4p F is an instantaneous residual current release designed for ABB SACE Tmax XT3 moulded case circuit breakers. Identified by ABB order code 1SDA067129R1, it provides residual current protection for compatible fixed four-pole XT3 circuit breakers in low-voltage electrical distribution systems.

As part of the ABB SACE Tmax XT accessory range, the RC Inst unit is designed to detect residual current associated with leakage to earth and initiate circuit-breaker operation according to the protection settings. Its instantaneous protection characteristic makes it suitable for applications requiring prompt response to detected residual current conditions.

The 1SDA067129R1 is specifically designed for fixed 4-pole Tmax XT3 circuit breakers and has an operating voltage range of 85–690 V AC. It is manufactured for integration with the XT3 platform and specified in accordance with IEC 60947-2.

Key Advantages

  • Genuine ABB SACE Tmax XT3 protection accessory.
  • Provides instantaneous residual current protection.
  • Wide operating voltage range of 85–690 V AC.
  • Designed specifically for fixed 4-pole XT3 circuit breakers.
  • Supports earth leakage protection within low-voltage distribution systems.
  • Manufacturer-matched design for integration with the ABB Tmax XT3 platform.

Key Features

  • ABB SACE Tmax XT accessory range.
  • RC Inst instantaneous residual current release.
  • 85–690 V AC operating voltage range.
  • Designed specifically for the XT3 frame size.
  • 4-pole configuration.
  • Designed for fixed circuit breakers.
  • Specified in accordance with IEC 60947-2.
  • ABB order code 1SDA067129R1.

Instantaneous Residual Current Protection for Tmax XT3

Residual current releases monitor an electrical circuit for an imbalance that can indicate current leakage to earth. When the applicable residual current protection threshold is reached, the release works with the circuit breaker to disconnect the circuit, supporting protection of the electrical installation against earth leakage faults.

The ABB RC Inst 1SDA067129R1 provides this functionality for compatible fixed four-pole Tmax XT3 circuit breakers. Its dedicated XT3 design, instantaneous operating characteristic and 85–690 V AC operating range make it suitable for professional industrial and commercial low-voltage distribution assemblies.

Typical Applications

  • ABB Tmax XT3 fixed four-pole circuit-breaker installations.
  • Industrial low-voltage distribution systems.
  • Commercial electrical switchboards.
  • Residual current and earth leakage protection.
  • Power distribution panels requiring instantaneous residual current protection.
  • OEM machinery and industrial electrical assemblies.

Technical Specifications

Series SACE Tmax XT
Extended product type RC Inst HV 85...690Vac XT3 4p F
Product type Instantaneous residual current release
ABB order code 1SDA067129R1
Accessory type Residual current device
Operating voltage 85–690 V AC
Compatible frame size XT3
Number of poles 4
Circuit-breaker configuration Fixed
Standard IEC 60947-2
UPC / GTIN 8015644010362
Net weight approx. 1.875 kg

Frequently Asked Questions

What is the ABB 1SDA067129R1 used for?

The ABB 1SDA067129R1 is an instantaneous residual current release designed for compatible fixed four-pole ABB SACE Tmax XT3 moulded case circuit breakers.

Which circuit breaker is compatible with the ABB RC Inst 1SDA067129R1?

The unit is specifically designed for compatible fixed 4-pole ABB SACE Tmax XT3 circuit breakers.

What is the operating voltage range of the ABB 1SDA067129R1?

The RC Inst residual current release has an operating voltage range of 85–690 V AC.

What does RC Inst mean on the ABB 1SDA067129R1?

RC Inst identifies this accessory as an instantaneous residual current release for the compatible Tmax XT circuit-breaker configuration.

Which standard applies to the ABB 1SDA067129R1?

The ABB RC Inst x XT3 4p F is specified in accordance with IEC 60947-2.

Trusted by Electrical Panel Builders Worldwide

ABB SACE Tmax XT protection accessories are widely used by switchboard manufacturers, electrical contractors and industrial panel builders to integrate manufacturer-matched residual current and circuit protection into professional low-voltage power distribution systems.