1SDA068066R1 ABB XT3N 250 TMD 250-2500 4p F F InN=50% Moulded Case Circuit Breaker

1SDA068066R1 ABB XT3N 250 TMD 250-2500 4p F F InN=50% Moulded Case Circuit Breaker

ABB 1SDA068066R1 XT3N 250 TMD 250-2500 4p F F InN=50% is a 250 A four-pole fixed moulded case circuit breaker with front terminals, TMD thermomagnetic overload and short-circuit protection, 50% neutral protection and 36 kA breaking capacity at 415 V AC.

SKU: 1SDA068066R1MPN: 1SDA068066R1
Price
List Price £1,205.14 ex VAT
Your Price (ex VAT) Save 25%
£903.86 25% OFF
You save £301.29 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £903.86
Trade pricing is personalised to your account

Manufacturer Lead Time

£903.86

Why Choose the ABB XT3N 250 TMD 250-2500 4p F F InN=50% Circuit Breaker?

The ABB XT3N 250 TMD 250-2500 4p F F InN=50%, order code 1SDA068066R1, is a four-pole moulded case circuit breaker (MCCB) designed for dependable protection of low-voltage power distribution systems. Part of the ABB SACE Tmax XT series, it combines the XT3 frame with a thermomagnetic TMD release, fixed mounting and front terminals for straightforward integration into industrial and commercial switchboards.

The breaker has a 250 A rated current and a TMD thermomagnetic release designated 250-2500 A, combining thermal overload protection with magnetic short-circuit protection. Its fourth pole has a neutral protection rating of 50% of the phase setting, making this specific configuration suitable for four-wire distribution systems where reduced neutral protection is appropriate.

The XT3N designation identifies the N interruption-performance level of the Tmax XT3 platform. This model has a rated operational voltage up to 690 V and the XT3N configuration provides an ultimate short-circuit breaking capacity of 36 kA at 415 V AC, delivering robust circuit protection in a compact fixed MCCB format.

Key Advantages

  • Robust four-pole moulded case circuit breaker for low-voltage power distribution.
  • 250 A rated current for industrial and commercial feeder protection.
  • TMD thermomagnetic trip unit provides overload and short-circuit protection.
  • 2,500 A magnetic trip threshold for rapid response to high fault currents.
  • Neutral protection set at 50% of the phase rating for suitable four-wire systems.
  • 36 kA ultimate breaking capacity at 415 V AC.
  • Rated for operation up to 690 V.
  • High mechanical durability of up to 25,000 operations.
  • Fixed mounting with front terminals supports straightforward panel integration.

Key Features

  • ABB SACE Tmax XT3 series.
  • XT3N 250 configuration with N-level interruption performance.
  • Four-pole configuration.
  • 250 A rated current.
  • TMD thermomagnetic release.
  • Thermal function: overload protection.
  • Magnetic function: instantaneous short-circuit protection.
  • Magnetic trip setting: 2,500 A.
  • Neutral protection: 50% of phase rating.
  • 690 V rated voltage.
  • 50/60 Hz rated frequency.
  • Fixed circuit-breaker construction with front terminal connections.

Thermomagnetic Protection for Power Distribution

Thermomagnetic moulded case circuit breakers provide two complementary forms of circuit protection without requiring an electronic trip unit. The thermal element responds to sustained overload currents, while the magnetic element operates rapidly during severe short-circuit conditions. On the ABB XT3N 250 TMD 250-2500, the 250 A release is combined with a 2,500 A magnetic trip level to provide dependable feeder and distribution protection.

This four-pole version also incorporates 50% neutral protection, meaning the neutral pole is protected at half the phase-current rating. Combined with the compact Tmax XT3 construction, fixed mounting, front terminals and 36 kA Icu at 415 V AC, the 1SDA068066R1 is well suited to distribution boards, switchboards and industrial power systems where robust thermomagnetic protection is required.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Four-wire three-phase distribution circuits.
  • Electrical switchboards and distribution boards.
  • Main and sub-main feeder protection.
  • Commercial building electrical distribution.
  • Industrial machinery power distribution.
  • Infrastructure and utility installations.
  • OEM electrical equipment and panel building.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA068066R1
Alternate catalogue number XT3NEN250AFF000XXX
Product type Moulded case circuit breaker
Application Power distribution
Frame size XT3
Frame designation 250
Interruption rating N
Number of poles 4
Rated current (In) 250 A
Trip unit TMD
Release technology Thermomagnetic
Protection functions Thermal overload and magnetic short-circuit protection
Magnetic trip current 2,500 A
Magnetic trip ratio 10 × In
Neutral protection (InN) 50% of phase rating
Neutral rated protection current 125 A
Rated voltage 690 V
Rated frequency 50/60 Hz
Ultimate breaking capacity (Icu) at 415 V AC 36 kA
Power loss 17.8 W
Electrical durability 8,000 operations
Electrical operating rate 120 operations/hour
Mechanical durability 25,000 operations
Mechanical operating rate 240 operations/hour
Mounting Fixed
Terminal connection Front
Dimensions (W × H × D) 140 × 150 × 70 mm
Net weight approx. 2.094 kg
EAN / UPC 8015644019679
Customs tariff number 85362090
Minimum order quantity 1 piece
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA068066R1 used for?

The ABB 1SDA068066R1 is a 250 A four-pole moulded case circuit breaker designed to provide thermomagnetic overload and short-circuit protection for low-voltage power distribution systems.

What protection does the TMD release provide?

The TMD thermomagnetic release combines thermal protection against sustained overloads with magnetic protection against high short-circuit currents. This model has a rated current of 250 A and a magnetic trip level of 2,500 A.

What does InN=50% mean on the ABB XT3N 250?

InN=50% means the neutral pole protection is rated at 50% of the phase-current setting. For this 250 A breaker, this corresponds to 125 A neutral protection.

What is the breaking capacity of the ABB XT3N 250?

The XT3N interruption level provides an ultimate short-circuit breaking capacity of 36 kA at 415 V AC, making the breaker suitable for a wide range of industrial and commercial distribution applications.

How is the ABB 1SDA068066R1 installed?

The XT3N 250 TMD 250-2500 4p F F InN=50% is a fixed four-pole circuit breaker with front terminals. Its dimensions are approximately 140 × 150 × 70 mm, supporting compact integration into switchboards and distribution panels.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for compact, robust and dependable protection of low-voltage electrical distribution systems.