ABB SU203M-C63 is a 63 A three-pole C-curve SU200M miniature circuit breaker with a 10 kA UL 489 interrupting rating at 240 V AC and 96 V DC for industrial branch circuit protection.
£210.12
The ABB SU203M-C63 is a high-performance three-pole miniature circuit breaker (MCB) designed for reliable branch circuit protection in industrial machinery, automation systems and electrical distribution equipment. As part of the ABB System pro M compact SU200M series, it combines a 63 A rated current with C-curve tripping characteristics and UL 489 branch circuit protection.
The SU203M-C63 provides thermal-magnetic protection against overloads and short circuits. Its C tripping characteristic makes it suitable for a broad range of general industrial loads with moderate inrush currents, providing dependable protection while accommodating normal switching and starting conditions.
With a rated current of 63 A, a three-pole configuration and a 10 kA UL 489 interrupting rating at 240 V AC and 96 V DC, the SU203M-C63 provides robust branch circuit protection. It also offers a rated ultimate short-circuit breaking capacity of 15 kA at 400 V AC according to IEC/EN 60947-2.
Miniature circuit breakers such as the ABB SU203M-C63 automatically disconnect protected circuits when overload or short-circuit conditions occur. Its thermal-magnetic operating principle combines thermal overload protection with rapid magnetic fault-current protection, helping safeguard conductors, machinery and electrical equipment against damaging overcurrents.
The C characteristic provides a practical balance between sensitivity and tolerance of normal inrush currents, making the SU203M-C63 suitable for a broad range of industrial loads. Combined with UL 489 branch circuit protection and UL, CSA and IEC compliance, it provides a versatile solution for machinery builders, panel builders and industrial automation applications.
Tick the specs you need, then view products that match.
| Certification | UL 489 | |
|---|---|---|
| Series | SU200M / System pro M compact | |
| ABB order code | 2CDS273337R0634 | |
| Product type | Miniature circuit breaker / branch circuit breaker | |
| Product group | UL489 / UL1077 MCB | |
| Rated current | 63 A | |
| Number of poles | 3 | |
| Number of protected poles | 3 | |
| Tripping characteristic | C | |
| Protection type | Thermal-magnetic overload and short-circuit protection | |
| UL 489 interrupting rating | 10 kA at 240 V AC and 96 V DC | |
| Rated operational voltage | 400 V AC according to IEC 60947-2 | |
| UL rated voltage | 240 V AC / 96 V DC | |
| Rated ultimate short-circuit breaking capacity (Icu) | 15 kA at 400 V AC | |
| Rated service short-circuit breaking capacity (Ics) | 7.5 kA at 400 V AC | |
| Rated insulation voltage | 440 V | |
| Rated impulse withstand voltage | 4 kV | |
| Rated frequency | 50 / 60 Hz and DC | |
| Standards | UL 489, CSA 22.2 No. 5, IEC/EN 60947-2 | |
| Energy limiting class | 3 | |
| Pollution degree | 3 | |
| Overvoltage category | III | |
| Contact position indication | Red ON / Green OFF | |
| Degree of protection | IP20; IP40 when installed in an enclosure with cover | |
| Power loss | 16.2 W total; 5.4 W per pole at rated operating conditions | |
| Mechanical endurance | 20,000 cycles | |
| Connecting capacity | Up to 35 mm² rigid or stranded conductor | |
| Tightening torque | 2.8 N·m | |
| Mounting type | DIN rail mounting | |
| DIN rail | TH35-7.5 or TH35-15 according to IEC 60715 | |
| Terminal type | Failsafe bi-directional cylinder-lift terminal | |
| Dimensions (H × W × D) | 111 × 52.5 × 69 mm | |
| Weight | 0.375 kg | |
| EAN / UPC | 4016779931427 |
The ABB SU203M-C63 is a three-pole miniature circuit breaker designed to provide UL 489 branch circuit protection against overloads and short circuits in industrial machinery, automation equipment and electrical distribution systems.
The SU203M-C63 has a rated current of 63 A and uses a C tripping characteristic.
The SU203M-C63 has a 10 kA UL 489 interrupting rating at 240 V AC and 96 V DC. According to IEC/EN 60947-2, its rated ultimate short-circuit breaking capacity is 15 kA at 400 V AC.
A C-curve MCB is suited to general-purpose circuits that can experience moderate inrush currents during normal operation. It provides thermal overload protection together with magnetic short-circuit protection while accommodating typical switching and starting currents.
The SU203M-C63 has a UL 489 rating of 240 V AC and 96 V DC with a 10 kA interrupting rating. Its rated operational voltage according to IEC 60947-2 is 400 V AC.
ABB System pro M compact SU200M miniature circuit breakers provide dependable UL 489 branch circuit protection for industrial machinery, automation systems and electrical distribution equipment, combining high short-circuit performance with compact modular construction and international standards compliance.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.