ABB SU202M-K5 is a 5 A two-pole K-characteristic miniature circuit breaker with a 10 kA short-circuit interrupting rating designed for UL 489 branch-circuit protection.

SKU: 2CDS272337R0357Alt SKU: SU202MK5MPN: 2CDS272337R0357
Price
List Price £147.08 ex VAT
Your Price (ex VAT) Save 25%
£110.31 25% OFF
You save £36.77 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £110.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£110.31

Why Choose the ABB SU202M-K5 Miniature Circuit Breaker?

The ABB SU202M-K5 is a compact 2-pole miniature circuit breaker (MCB) designed to provide branch-circuit protection against overload and short-circuit currents. With a rated current of 5 A, K tripping characteristic and 10 kA short-circuit interrupting rating, it is suited to industrial control, automation and equipment circuits requiring UL 489 protection.

Its K tripping characteristic combines thermal overload protection with magnetic short-circuit protection while accommodating temporary starting currents associated with appropriate inductive loads. This makes the SU202M-K5 particularly useful for selected control circuits, transformers, solenoids and other industrial loads where normal energisation can produce elevated short-duration current.

The SU202M-K5 is specified as a UL 489 miniature circuit breaker, enabling it to be applied for branch-circuit protection when correctly selected and installed. Its two-pole configuration and compact modular construction support straightforward DIN-rail integration into machinery, OEM equipment and industrial electrical control panels.

Key Advantages

  • UL 489 miniature circuit breaker for branch-circuit overcurrent protection.
  • 5 A rated current for appropriately rated industrial circuits.
  • 2-pole configuration for coordinated circuit switching and protection.
  • K tripping characteristic suited to appropriate inductive loads and circuits with elevated starting currents.
  • 10 kA short-circuit interrupting rating for dependable fault protection.
  • Compact DIN-rail construction supports efficient installation in industrial control panels.

Key Features

  • ABB SU200M miniature circuit breaker series.
  • 2-pole configuration.
  • 5 A rated current.
  • K characteristic thermal-magnetic tripping.
  • 10 kA short-circuit interrupting rating.
  • UL 489 circuit breaker classification.
  • Automatic overload and short-circuit interruption.
  • Resettable operation following clearance of a fault condition.
  • Modular construction for DIN-rail mounting.

Reliable Branch-Circuit Protection for Industrial Circuits

The ABB SU202M-K5 uses thermal-magnetic protection to respond to both sustained overloads and short-circuit faults. Its thermal element reacts to prolonged excessive current, while magnetic operation provides rapid interruption during high fault-current conditions, helping protect appropriately rated conductors and connected electrical equipment.

The combination of a 5 A rating and K characteristic makes this model suitable for selected industrial circuits where temporary starting or inrush current must be accommodated. Its compact two-pole DIN-rail construction supports convenient integration into automation systems, machinery and OEM control cabinets.

Typical Applications

  • Industrial machinery and automation panels.
  • Control and auxiliary circuits.
  • Selected inductive electrical loads.
  • Control transformers and solenoid circuits.
  • OEM electrical and automation equipment.
  • Branch circuits requiring a 5 A K-characteristic UL 489 miniature circuit breaker.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series SU200M
ABB order code 2CDS272337R0357
Product type Miniature circuit breaker
Number of poles 2P
Rated current 5 A
Tripping characteristic K
Short-circuit interrupting rating 10 kA
Protection principle Thermal-magnetic
Standard UL 489
Mounting type DIN rail

Frequently Asked Questions

What is the ABB SU202M-K5 used for?

The SU202M-K5 is a 2-pole miniature circuit breaker designed to provide overload and short-circuit protection for appropriately rated branch circuits in industrial equipment, machinery and control systems.

What is the rated current of the ABB SU202M-K5?

The ABB SU202M-K5 has a rated current of 5 A.

What does the K characteristic mean?

The K tripping characteristic is suited to appropriate inductive loads and circuits with elevated temporary starting currents, helping accommodate normal start-up conditions while retaining thermal-magnetic overcurrent protection.

What is the short-circuit rating of the SU202M-K5?

The SU202M-K5 has a specified short-circuit interrupting rating of 10 kA.

Is the ABB SU202M-K5 a UL 489 circuit breaker?

Yes. The SU202M-K5 is specified as a UL 489 miniature circuit breaker for branch-circuit protection when selected and installed in accordance with the applicable electrical requirements.