2CCG000121R0001 ABB SUP403M-K4 MCB 10 kA 3P K 4 A UL489

2CCG000121R0001 ABB SUP403M-K4 MCB 10 kA 3P K 4 A UL489

ABB SUP403M-K4 is a 4 A 3-pole K-characteristic pluggable miniature circuit breaker with a 10 kA UL 489 short-circuit interrupting rating for 277/480 V AC SMISSLINE TP branch circuit protection.

SKU: 2CCG000121R0001Alt SKU: SUP403MK4MPN: 2CCG000121R0001
Price
List Price £249.20 ex VAT
Your Price (ex VAT) Save 35%
£161.98 35% OFF
You save £87.22 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £161.98
Trade pricing is personalised to your account

Manufacturer Lead Time

£161.98

Why Choose the ABB SUP403M-K4 Miniature Circuit Breaker?

The ABB SUP403M-K4 is a pluggable 3-pole miniature circuit breaker (MCB) designed for branch circuit protection within ABB SMISSLINE TP electrical distribution systems. As part of the ABB SUP400M series, it combines UL 489 circuit protection with the modular plug-in architecture of the SMISSLINE TP system for professional industrial and commercial electrical distribution.

This MCB has a rated current of 4 A, a K tripping characteristic and a UL 489 short-circuit interrupting rating of 10 kA. Its three-pole configuration provides coordinated protection for compatible three-phase circuits, while the K characteristic is suitable for applications where connected equipment may produce elevated starting or inrush currents.

Designed for 277/480 V AC systems, the SUP403M-K4 plugs into the compatible ABB SMISSLINE TP socket-base system. Its compact three-module construction supports efficient panel assembly, straightforward circuit configuration and dependable overload and short-circuit protection.

Key Advantages

  • Pluggable miniature circuit breaker for ABB SMISSLINE TP distribution systems.
  • 4 A rated current for branch circuit protection.
  • 3-pole configuration suitable for compatible three-phase circuits.
  • K tripping characteristic suitable for loads with increased starting currents.
  • 10 kA short-circuit interrupting rating according to UL 489.
  • Designed for 277/480 V AC systems.
  • UL 489 compliant for branch circuit protection.
  • Plug-in architecture supports efficient installation within SMISSLINE TP assemblies.

Key Features

  • ABB SUP400M series miniature circuit breaker.
  • 4 A rated current.
  • 3 protected poles.
  • K characteristic overcurrent tripping.
  • 10 kA UL 489 breaking capacity.
  • Suitable for 277/480 V AC systems.
  • 50–60 Hz rated frequency.
  • 4 kV rated impulse withstand voltage.
  • Compact 3-module construction.
  • Pluggable mounting for the ABB SMISSLINE TP system.

Reliable Three-Phase Branch Circuit Protection

Miniature circuit breakers protect electrical circuits against excessive current caused by overload and short-circuit conditions. The ABB SUP403M-K4 combines these protective functions with a K tripping characteristic, making it suitable for appropriate circuits where connected equipment can draw increased current during starting or energisation.

As a pluggable SMISSLINE TP protective device, the SUP403M-K4 integrates directly into compatible socket-base assemblies. This modular architecture supports efficient panel construction and circuit configuration, while the three-pole design provides coordinated branch circuit protection for compatible three-phase electrical loads.

Typical Applications

  • ABB SMISSLINE TP electrical distribution systems.
  • UL 489 branch circuit protection.
  • Three-phase industrial branch circuits.
  • Industrial electrical distribution panels.
  • Commercial electrical distribution systems.
  • Control and automation panels.
  • Circuits supplying suitable loads with elevated starting or inrush currents.
  • 277/480 V AC distribution applications.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series SUP400M
Product group SMISSLINE Plug-in System
ABB order code 2CCG000121R0001
EAN / GTIN 7612271506636
Product type Pluggable miniature circuit breaker (MCB)
Rated current 4 A
Number of poles 3
Number of protected poles 3
Tripping characteristic K
Short-circuit interrupting rating 10 kA
System voltage 277/480 V AC
Frequency 50–60 Hz
Standard UL 489
Application Branch circuit protection
Rated impulse withstand voltage 4 kV
Overvoltage category III
Pollution degree 2
Operating ambient temperature -25 to +60 °C
Solid conductor connection 0.75–35 mm²
Stranded conductor connection 0.75–25 mm²
Modules 3
Product width 54 mm
Installation depth 102 mm
Product weight 360 g
Packaging unit 3 pieces
Compatible system ABB SMISSLINE TP

Frequently Asked Questions

What is the ABB SUP403M-K4 used for?

The SUP403M-K4 is a UL 489 pluggable miniature circuit breaker designed to provide overload and short-circuit protection for three-pole branch circuits within ABB SMISSLINE TP electrical distribution systems.

What is the rated current of the SUP403M-K4?

The ABB SUP403M-K4 has a rated current of 4 A.

How many poles does the SUP403M-K4 have?

The SUP403M-K4 is a 3-pole MCB with three protected poles, making it suitable for compatible three-phase branch circuit applications.

What does the K characteristic mean on the SUP403M-K4?

The K tripping characteristic is suited to appropriate circuits where connected equipment may produce increased starting or inrush currents while still requiring dependable overload and short-circuit protection.

What is the breaking capacity of the ABB SUP403M-K4?

The SUP403M-K4 has a UL 489 short-circuit interrupting rating of 10 kA.

Engineered for ABB SMISSLINE TP Distribution

ABB SUP400M K-characteristic miniature circuit breakers combine UL 489 branch circuit protection with the flexible plug-in architecture of the SMISSLINE TP system, providing dependable three-pole overcurrent protection for professional electrical distribution assemblies.